Specifications

Command Set 3-53
3. 40. Change Leading Code Setting
@Description
User can use this command to change command leading code setting
as he desired.
@Syntax
~(Addr)10(C1)(C2)(C3)(C4)(C5)(C6)<CR>
~
Command leading code.
(Addr) Address ID, range (00 - FF).
10 Change command leading code setting.
(C1) Leading code 1, for read configuration status,
firmware version, etc. default is $.
(1-character)
(C2) Leading code 2, for read synchronize sampling,
digital output ,default is #.
(1-character)
(C3) Leading code 3, for change configuration.
default is %. (1-character)
(C4) Leading code 4, for read alarm status, enable
alarm, etc. default is @. (1-character)
(C5) Leading code 5, for read command leading code,
change leading code, etc. default is ~.
(1-character)
(C6) Leading code 6, this leading code is reserved.
default is *. (1-character)
@Response
!(Addr)< CR>
or
?(Addr)<CR>
! Command is valid.
? Command is invalid.
(Addr) Address ID.
(6011/D, 6012/D, 6013
6014D, 6017, 6018)