User`s manual

Hardware Reference 13
13
13
RTV-I4 Connectors & Pin Definitions
Relay output signal select:
Relay output types: Normal open or Normal closed
Signal names: RY1, RY2, RY3, RY4
Jumper addresses: J5, J6, J7, J8
Type select: Normal open: 2-3, Normal close: 1-2
Normal Open Normal Closed
1 2 3
J6
J5
J8
J7
Relay I/O voltage requirement:
Input: +5V to +24V
Output: AC: 0.5A/125V, DC: 1A/30V or 0.3A/100V