Owner manual

120 IPMI User Guide
9.5 Communications with IPMC
Operating systems need to use a serial port to communicate with
the IPMC. The resource setting of the serial port must be IO:
0x2F0 and IRQ: 7. The communication setting of the serial port
must be BaudRate: 9600, DataBit: 8, ParityCheck: None, StopBit:
1, and FlowControl: None. In Windows XP, use "COM6" to com-
municate with the IPMC.
9.6 IPMI Sensors List
Sensor
Number
Sensor name
Normal
Reading
Sensor Reading Value of
IPMI Get Sensor Reading
Command
01h BMC Watchdog
Timeout action:
000b = no action
001b = Hard Reset
000b = Power Down
011b = Power Cycle
100b - 111b = reserved
02h 3.3V 3.3 V Raw data of 3.3V sensor
03h 5V 5 V Raw data of 5.0V sensor
04h 12V 12 V Raw data of 12.0V sensor
05h CPU Temp 40ºC Raw data of CPU Temp sensor
06h SYSTEM Temp 25ºC
Raw data of SYSTEM Temp
sensor