36 • Power Supply Unit
Input Characteristics
• Input Voltage: Typ. 90-264VAC
• Power Factor Correction: Meets Harmonic Correction
EN 61000-3-2
.
• Input Connector: CompactPCI 47-pin power connector
• Input Frequency: 47-63Hz
• Inrush Current: Less than 15A@240VAC
• Input Current: 3.6A@230VAC/ 4A@260VAC
• EMI: Meets EN55022 / FCC Class A
• Hold-up Time: 20mS after power fail signal
• Remote ON/OFF: Available at [INH#] & [EN#] pins
• Power Fail Signal: Available at [FAL#] pin
• Status LED: <Green> means valid input voltage; <Amber> means a
critical fault.
• Thermal Protection (OTP): Installed NTC and thermostat for thermal
sensor at [DEG#] pin
• Power OK: Installed at all outputs
• Leakage Current: 1.18mA at 254VAC/60Hz
Output Characteristics
Output Current (A)
Output
Voltage
Min. Max. Typ. Peak
5V
0 40.0 25.0 –
3.3V
0 40 20 –
12V
0 5.5 4 –
-12V
0 2 1 –
• Over Load Protection: Fully protected against output overload or
short circuit. Typical 120% max. load.
• Over Current Protection: Installed at each rail
• Output Wattage: Typ. 250W continuous.
• Output Connector: CompactPCI 47-pin power connector.
• Line Regulation: Max. ±10mV
• Load Regulation: 3.3V & 5V: ± 10mV, +12V: ± 30mV & -12V: -380
mV.