40 Specifications
6.3 Environmental
Operating Temperature: -20°C to 50°C (Supports operation up to 70°C
but with derating above 50°C. Power efficiency will be derated by 2.5%
for every degree Celsius with only 50% power efficiency at 70°C, i.e.
125W/PSU.)
Storage Temperature: -40 to 85°C.
Humidity: 5% - 95%, non-condensed.
Shock: 15G peak-to-peak, 11ms duration, non-operation.
Vibration:
o Non-operation:1.88Grms, 5 – 500Hz, each axis.
o Operation: 0.5Grms, 5 – 500Hz, each axis.
6.4 System Alarm Board
Supports fault alarm for up to 8 fans. If any fan faults, the ALARM LED
will flash and an audible alarm will sound
Can detect temperature at two different locations.
Trigger temperature for each sensor can be set independently (50°C,
60°C, 70°C).
Alarm mute