Power Specifications
Table 2-5 provides the power requirements for the Express-HRR with 1.5, 2.1, and 2.2 GHz CPUs and a 430
watt power supply.
Operating configurations:
In-rush operating configuration includes video, baseboard, and 8GB DDR3 RAM.
Idle (Windows XP) operating configuration includes the in-rush configuration as well as one SATA
drive (external power), boot up from SATA0, keyboard and mouse.
BIT = Burn-In-Test. Operating configuration includes the Idle configuration as well as a second SATA
hard drive, four USB test plugs, two serial port loop backs, one Ethernet loop back, and two USB
Compact Flash readers with 64MB Compact Flash modules.
S1 (Standby) operating configuration is the same as BIT operating configuration.
S3 (Suspend) operating configuration is the same as BIT operating configuration.
Environmental Specifications
Table 2-6 provides the operating and storage temperature ranges required for this module.
Table 2-5. Power Supply Requirements
Parameter 1.5 GHz CPU 2.1 GHz CPU 2.2 GHz CPU
Input Type
(430 watt power supply)
+12V Regulated DC +12V Regulated DC +12V Regulated DC
In-rush Voltage & Current 3.52A (42.24W) 3.76A (45.12W) 7.18A (86.16W)
Typical Idle Voltage & Current
(Windows XP)
0.66A (7.90W) 0.65A (7.84W) 0.65A (7.78W)
BIT Voltage & Current 1.89A (22.65W) 4.80A (57.59W) 2.72A (32.63W)
S1 Mode 0.13A (0.64W) 0.11A (0.55W) 0.12A (0.60W)
S3 Mode 0.47A (2.37W) 0.46A (2.32W) 0.47A (2.33W)
Table 2-6. Environmental Requirements
Parameter Conditions
Temperature
Operating –20° to +70°C (–4° to +158°F)
Extended (Optional) –40° to +85°C (–40° to +185°F)
Storage –55° to +85°C (–67° to +185°F)
Humidity
Operating 5% to 90% relative humidity, non-condensing
Non-operating 5% to 95% relative humidity, non-condensing