Owner manual
Chapter 2 Product Overview
14 Reference Manual Express-HRR
Power Specifications
Table 2-5 provides the power requirements for the Express-HRR with 1.5, 2.1, and 2.2 GHz CPUs and a 430
watt power supply.
Operating configurations:
• In-rush operating configuration includes video, baseboard, and 8GB DDR3 RAM.
• Idle (Windows XP) operating configuration includes the in-rush configuration as well as one SATA
drive (external power), boot up from SATA0, keyboard and mouse.
• BIT = Burn-In-Test. Operating configuration includes the Idle configuration as well as a second SATA
hard drive, four USB test plugs, two serial port loop backs, one Ethernet loop back, and two USB
Compact Flash readers with 64MB Compact Flash modules.
• S1 (Standby) operating configuration is the same as BIT operating configuration.
• S3 (Suspend) operating configuration is the same as BIT operating configuration.
Environmental Specifications
Table 2-6 provides the operating and storage temperature ranges required for this module.
Table 2-5. Power Supply Requirements
Parameter 1.5 GHz CPU 2.1 GHz CPU 2.2 GHz CPU
Input Type
(430 watt power supply)
+12V Regulated DC +12V Regulated DC +12V Regulated DC
In-rush Voltage & Current 3.52A (42.24W) 3.76A (45.12W) 7.18A (86.16W)
Typical Idle Voltage & Current
(Windows XP)
0.66A (7.90W) 0.65A (7.84W) 0.65A (7.78W)
BIT Voltage & Current 1.89A (22.65W) 4.80A (57.59W) 2.72A (32.63W)
S1 Mode 0.13A (0.64W) 0.11A (0.55W) 0.12A (0.60W)
S3 Mode 0.47A (2.37W) 0.46A (2.32W) 0.47A (2.33W)
Table 2-6. Environmental Requirements
Parameter Conditions
Temperature
Operating –20° to +70°C (–4° to +158°F)
Extended (Optional) –40° to +85°C (–40° to +185°F)
Storage –55° to +85°C (–67° to +185°F)
Humidity
Operating 5% to 90% relative humidity, non-condensing
Non-operating 5% to 95% relative humidity, non-condensing