HPERC-IBR-HC/HH High Performance Extreme Rugged™ Computer System User’s Manual Manual Rev.: 0.10 Preliminary Revision Date: May 5, 2015 Part No: 50-1Z179-1000 Advance Technologies. Automate the World.
Revision History Revision 0.
HPERC-IBR-H Preface © Copyright 2015 ADLINK Technology, Inc. www.adlinktech.com Disclaimer Information in this document is provided in connection with ADLINK products. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document.
This page intentionally left blank.
HPERC-IBR-M Table of Contents Revision History................................................................................................................... ii Preface ................................................................................................................................. iii List of Figures .................................................................................................................... vii List of Tables ....................................................
This page intentionally left blank.
HPERC-IBR-H List of Figures Figure 1-1: Figure 1-2: Figure 1-3: Figure 1-4: Figure 1-5: Figure 1-6: Figure 2-7: Figure 2-8: Figure 2-9: Figure 2-10: Figure 2-11: Figure 2-12: Figure 2-13: Figure 2-14: Figure 2-15: Figure 2-16: List of Figures i7-3517UE Peak In-Rush Current and Duration...............................................................2 HPERC-IBR-H Unit with Accessories ..............................................................................
This page intentionally left blank.
HPERC-IBR-H List of Tables Table Table Table Table Table 1-1: 1-2: 1-3: 1-4: 1-5: List of Tables System Power Requirements ............................................................................................2 Environmental Requirements ............................................................................................3 I/O Panel Connectors (Refer to Figure 1-5 for connector locations.).................................9 Pin definitions and signal maps for the P2 Military Connector.......
This page intentionally left blank.
HPERC-IBR-H 1 HPERC-IBR-H Setup 1.1 About the HPERC-IBR-H The HPERC products are intended for users of embedded systems requiring long life-cycles, configuration control, and ruggedness in hardened military packages. HPERC models feature Extreme Rugged™ computer boards available with varieties of processors and memory. An optional operating system (OS) can be pre-loaded onto an optional internal storage device (two 2 ½" Solid State Drives (SSDs).
1.5 Power Specifications Table 1-1 defines the current draw values of the HPERC-IBR-H, featuring either the 3517UE, 3555LE, or 3612QE i7 CPUs. The table captures In-Rush, Idle, and Burn-In-Test (BIT) currents at +28V input voltage. Table 1-1 lists the current draw values of the HPERC-IBR-H Parameter 1.7GHz CPU (i7-3517UE) 2.5GHz CPU (i7-3555LE) 2.
HPERC-IBR-H 1.6 Environmental Specifications Table 1-2 provides the most efficient operating and storage condition ranges required for this system. NOTE: Extended temperature range available only on extended temperature tested (ETT) systems.
1.7 What’s in the Box The Contents List identifies the items in the shipping box for the HPERC-IBR-H Unit and HPERC-IBR-H Accessories (sold separately.) See Figure 1-2.
HPERC-IBR-H 1.8 Setup Steps Follow the setup steps in this section in the order listed. Skip any steps that do not apply to your application. 1) Open shipping box. 2) Verify contents. • Locate the HPERC-IBR-H Contents List. • Unpack the contents of the shipping box. • Verify the contents of the shipping box against the Contents List included with your HPERC-IBR-H. • If anything is missing or damaged, call your sales representative. Refer to the ADLINK web page at www.adlinktech.
1.10 Installing Mounting Screws 5) Install mounting screws. • Install mounting screws (not included) for surface or wall mounting to the mounting flanges of the HPERC-IBR-H. See Figure 1-3 and Figure 1-4. Mounting Screws: 3/8" - 16 (M10x1.
HPERC-IBR-H Mounting Screws: 1/4" - 20 (M6x1) Figure 1-4: Top and Front Views of “HC” Enclosure with Mounting Dimensions HPERC-IBR-H Setup 7
1.11 Connecting Peripherals 6) Connect the appropriate military breakout cable to the corresponding HPERC-IBR-H military connector. See Figure 1-2 for illustrations of cables. See Figure 1-5 for locations of the HPERC-IBR-H military connectors. • Refer to Figure 1-5 for locations and descriptions of the connectors before making connections or powering on the HPERC-IBR-H. • Connect the USB or PS2 keyboard to the corresponding connector on the appropriate breakout cable.
HPERC-IBR-H Control/Connector P1 DC Power In This Military Power connector accepts DC voltages from an external source. NOTE: This connector is manufactured by Amphenol. GND HPERC_DC_In_Pinout_b GND V+ A B D C Description V+ P2 Military Connector This military connector provides signals for Ethernet Ports, USB 2.0, Serial Ports, Reset Switch, Ethernet LEDs, and UNDIO.
1.12 P2 and P3 Military Connector The following two tables define the signals and signal maps of the two military I/O connectors (P2 and P3) on the HPERC-IBR-H. Each table lists the P2 or P3 pin numbers, the signal names and descriptions and the corresponding pins of the internal IO boards (HIBR and Interface Board.) Figure 1-6 provides the number and location of each pin on the two military connectors.
HPERC-IBR-H 1.12.1 P2 Pin Definitions MIL-DTL38999 Pin A5 A6 A7 A8 A9 A10 A11 A12 A13 A14 B2 B3 B4 B5 B6 B7 B8 B9 B10 B11 B12 B13 B14 B15 B16 B17 C1 C2 C3 C4 C5 C6 C7 C8 C9 C10 C11 C12 C13 C14 C15 C16 C17 C18 D1 D2 D3 D4 D5 D6 Breakout Connector Pin # Bussed N/C 9 USB3_TX2P 8 USB3_TX2N Ground 7 USB 3.0 Port2 USB3_RX2P 6 USB 2 USB3_RX2N 5 Ground 4 USB_N2 2 USB 2.0 Port2 USB_P2 3 Bussed N/C Bussed N/C USB3_TX3N 8 USB3_TX3P 9 Ground 7 USB 3.0 Port3 USB3_RX3P 6 USB 3 5 USB3_RX3N Ground 4 2 USB_N3 USB 2.
MIL-DTLFunction Port Signal 38999 Pin D7 Bussed D8 ERASE-L D9 HDC_RUN-L D10 Ground RS-422 Port2 DB9 2 D11 RS422_RX2_N D12 RS422_RX2_P D13 Bussed D14 RS422_TX4_N RS-422 Port4 DB9 4 D15 RS422_TX4_P D16 Bussed D17 TMDS ClockHDMI Port B HDMI B D18 TMDS Clock+ D19 TMDS Clock Shield E1 Ground E2 ESATA_TX-P1 E3 ESATA_TX-N1 eSATA Port1 eSATA 1 E4 Ground E5 ESATA_RX-P1 E6 ESATA_RX-N1 E7 Ground E8 RS422_TX7_P RS-422 Port7 DB9 7 E9 E10 Bussed E11 RS422_TX2_P RS422 Port2 DB9 2 E12 RS422_TX2_N E13 Bussed E14 UDNIO16 Twi
HPERC-IBR-H MIL-DTL38999 Pin G1 G2 G3 G4 G5 G6 G7 G8 G9 G10 G11 G12 G13 G14 G15 G16 G17 G18 H2 H3 H4 H5 H6 H7 H8 H9 H10 H11 H12 H13 H14 H15 H16 H17 I6 I7 I8 I9 I10 I11 I12 I13 I14 I15 Function Port Signal Power LED Power LED SATA LED SATA LED Keyboard Keyboard Diff.
1.12.2 P3 Pin Definitions MIL-DTL38999 Pin A5 A6 A7 A8 A9 A10 A11 A12 A13 A14 B2 B3 B4 B5 B6 B7 B8 B9 B10 B11 B12 B13 B14 B15 B16 B17 C1 C2 C3 C4 C5 C6 C7 C8 C9 C10 C11 C12 C13 C14 C15 C16 C17 C18 D1 D2 D3 D4 D5 D6 Function Port DVI D DVI PortD RJ-45 4 LED LAN Port4 DVI C DVI PortC DVI C DVI PortC DVI D DVI PortD LAN Port4 RJ-45 4 LED LAN Port5 DVI C DVI PortC Diff. Twisted Pair-8 Diff.
HPERC-IBR-H MIL-DTL38999 Pin D7 D8 D9 D10 D11 D12 D13 D14 D15 D16 D17 D18 D19 E1 E2 E3 E4 E5 E6 E7 E8 E9 E10 E11 E12 E13 E14 E15 E16 E17 E18 E19 F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11 F12 F13 F14 F15 F16 F17 F18 F19 Function RJ-45 5 USB 4 USB 5 RJ-45 4 DVI D DVI C DB9 1 RJ-45 5 RJ-45 4 RJ-45 4 USB8 VGA Diff. DB9 0 Diff. Diff. Breakout Connector Pin # Bussed N/C GBE5_MDI0_1_P 3 LAN Port5 GBE5_MDI0_1_N 6 Bussed N/C P5V_USB4_CON 1 USB 2.0 Port4 Power P5V_USB5_CON 1 USB 2.
MIL-DTL38999 Pin G1 G2 G3 G4 G5 G6 G7 G8 G9 G10 G11 G12 G13 G14 G15 G16 G17 G18 H2 H3 H4 H5 H6 H7 H8 H9 H10 H11 H12 H13 H14 H15 H16 H17 I6 I7 I8 I9 I10 I11 I12 I13 I14 I15 Function Port Signal CRT_RED_CONN CRT_HSYNC VGA VGA Ground (HSYNC) CRT_VSYNC VGA & DVI C/D Powe P5V DVI PortC/D Analog Ground DVI C/D UDNIO14 Diff. Twisted Pair-2 UDNIO13 Ground RS422 Port2 DB9 0 RS422_RX0_P RS422_RX0_N Bussed USB_N5_CONN USB 2.0 Port5 USB 5 USB_P5_CONN Ground USB_N9_CONN USB 2.
HPERC-IBR-H 1.13 Applying Power to the HPERC-IBR-H 7) Follow these steps to apply power to the HPERC-IBR-H. • Connect the AC Mating Cable to the AC Adapter (options.) See Figure 1-2. • Plug in the DC Cable Connector from the AC Adapter (option) to the DC IN jack onthe HPERC-IBR-H. See Figure 1-5. CAUTION: Power supplied to the unit must be within the allowed range depending on the model of the unit: • +10VDC to +36VDC CAUTION: Failure to provide proper power may damage the system and void the warranty.
This page intentionally left blank.
HPERC-IBR-H 2 Internal Components This chapter discusses the optional components inside the HPERC-IBR-H enclosure. These components include the SSDs (Solid State Drives), the SD Memory Card, the PCI/104-Express expansion module, the SODIMM memory, and the Mini PCIe Card. 2.1 HPERC-IBR-H Assembly Procedures The following procedures describe how to remove and install the HPERC-IBR-H internal components.
2.1.3 Replacing the SSDs (Solid State Drives) The SSD slots are two of three externally accessible component slots on the enclosure. The other externally accessible component slot is the SD memory card slot. SSDs allow you to install an OS and store data for the system. To remove the SSDs (if installed) from the enclosure side panel 1) Shut down the system as described earlier in Shutting Down the HPERC-IBR-H. 2) Remove the screws mounting the SSD cover plate as shown in Figure 2-7.
HPERC-IBR-H 2.1.4 Replacing the SD (Secure Digital) Memory Card The SD memory card slot is one of three externally accessible component slots on the enclosure. The other externally accessible component slots are the SSD slots. The SD card allows you to store data or install an operating system. To remove the SD card from the enclosure side panel 1) Shut down the system and disconnect the enclosure from the power source as described earlier in Shutting Down the HPERC-IBR-H.
2.1.5 sure Removing and installing the system cover plate on the HPERC-IBR-H enclo- The system cover plate allows you access to the internal components of the HPERC-IBR-H. To remove the system cover plate from the enclosure 1) Shut down the system as described earlier in Shutting Down the HPERC-IBR-H. 2) 3) Remove the screws holding the system cover plate to the enclosure as shown in Figure 2-9. Remove the system cover plate as shown.
HPERC-IBR-H 2.1.6 Replacing the PCI/104-Express expansion module The HPERC-IBR-H allows for expandable IO with a slot for a stackable PCI/104-Express module, which is removable and can accommodate other stackable expansion boards. The PCI/ 104-Express slot resides under the SSD bracket. Make sure to perform each of the steps in the following procedure to replace a PCI/104-Express module.
4) Remove the PCI/104-Express module mounting screws and module as shown in Figure 2-11. Mounting Screws PCI/104-Express Module Figure 2-11: Exploded View of HPERC-IBR-H with PCI/104-Express Module and Screws To install the PCI/104-Express module 1) Align the mounting holes on the module with the corresponding holes on the enclosure and install mounting screws as shown in Figure 2-11. 2) 24 Replace components removed in previous steps in reverse order.
HPERC-IBR-H 2.1.7 Replacing the SODIMM memory The HPERC-IBR-H features one SODIMM socket for up to 8GB of DDR3 memory, providing a 64-bit wide channel for un-buffered, ECC memory. To remove the SODIMM from the enclosure 1) Shut down the system and disconnect the enclosure from the power source as described earlier in Shutting Down the HPERC-IBR-H. 2) Remove the SSDs, system cover plate, SSD bracket, PCI/104-Express module as described above.
4) Disconnect the FPC connector from its mating connector on the system and remove the power connector as shown in Figure 2-13.
HPERC-IBR-H 5) Remove the screws securing the interface board to the system, and remove the interface board as shown in Figure 2-15.
6) Remove the SODIMM cover plate and SODIMM as shown in Figure 2-15. Make sure to take ESD precautions when handling the SODIMM. SODIMM Cover Plate SODIMM Figure 2-15: Exploded View of HPERC-IBR-H with SODIMM and Cover Plate To install the SODIMM 1) Install the SODIMM into the socket as keyed. 2) 28 Install the SODIMM cover plate.
HPERC-IBR-H 2.1.8 Replacing the Mini PCIe Card The HPERC-IBR-H features one Mini PCIe Card slot for high-speed serial I/O capability. To remove the Mini PCIe Card from the enclosure 1) Shut down the system and disconnect the enclosure from the power source as described earlier in Shutting Down the HPERC-IBR-H. 2) 3) Remove the SSDs, system cover plate, SSD bracket, PCI/104-Express module as described earlier. The FPC connector does not need to be disconnected.
This page intentionally left blank.
HPERC-IBR-H Getting Service ADLINK “Ask an Expert” is a comprehensive support center designed to meet all your technical needs. This service is free and available at http://www.adlinktech.com/AAE/, and includes a searchable database of Frequently Asked Questions, which will help you with the common information requested by most customers. Contact us should you require any service or assistance. ADLINK Technology, Inc. Address: 9F, No.
ADLINK Technology, Inc. (French Liaison Office) Address: 6 allée de Londres, Immeuble Ceylan 91940 Les Ulis, France Tel: +33 (0) 1 60 12 35 66 Fax: +33 (0) 1 60 12 35 66 Email: france@adlinktech.com ADLINK Technology Japan Corporation Address: ͱ101-0045 ᵅҀ䛑गҷ⬄ऎ⼲⬄䤯 ⬎ފ3-7-4 ⼲⬄ 374 ɛɳ 4F KANDA374 Bldg. 4F, 3-7-4 Kanda Kajicho, Chiyoda-ku, Tokyo 101-0045, Japan Tel: +81-3-4455-3722 Fax: +81-3-5209-6013 Email: japan@adlinktech.com ADLINK Technology, Inc.