Owner manual
Introduction • 3
C: 0°C~2320°C
• Voltage Range: Programmable 6 levels
±2.5V, ±1V, ±500mV, ±100mV, ±50mV, ±15mV
• Current Measurement: ±20mA (with external 125Ω resistor)
• Accuracy: ±0.4%
Note
(1)
: F/W version above A4.60 support K-type for 0~1370
°
C. Lower version
supports K-type for 0~1000
°
C.
Digital Output
• Channel numbers: 2
• Output characteristic: open collector transistor
• Maximum current sink: 50mA
• Max. power dissipation: 300mW
Digital Input
• Channel numbers: 1
• Logical level 0: +1V maximum
• Logical level 1: +2.0V~ +30V
• Pull up resister: 10KΩ
• Maximum current: 0.5mA
Watchdog Function
• Module internal watchdog timer: 150 ms
• Power failure threshold: 4.65 V
• Safety value: 2 digital output channels
• Host programmable watchdog: 100 ms ~ 25.500 sec
Power
• Power supply: +10V to +30V
• Current consumption: 0.76W(1.68W for NuDAM-6011/D)