3.8 Digital Output
( 6050, 6060, 6063 )
@Description
Set digital output channel value at specified address. This command is
only available to modules involving the digital output function.
@Syntax
#(Addr)(ChannelNo)(OutData)<CR> (6050,6060,6063 Only)
# Command leading code. (1-character)
(Addr) Address ID (2-character)
(ChannelNo)
00 : Set value to all channels
1X : Set value to single channel
First character is 1, Second character is
channel number. (2-character)
(OutData)
Set value to all channels :
Each bit is mapping to each channel number
Set value to single channel :
First character is 0, second character is set to value 0
or 1. (2-character)
@Response
<CR>
or
?(Addr)<CR>
> Command is valid
? Command is invalid.
(Addr) Address ID.
@Example
User command: #300003<CR>
Response: ><CR>
30 Address ID
00 Set output to all channels
03
03 (00000011), Channel 0 and 1 are set ON other
channels are set to OFF