User Manual

76 Command Set
@Example
User command: #30H31<CR> (for ND-6056)
Response: <CR>
30 Address ID
H Set output to high byte
3 Channel number is 3, that is channel 11
1 Set corresponding channel to ON
User command: #2FA20<CR>
Response: <CR>
2F Address ID
A Set output to port A
2 Channel number is 2
0 Set corresponding channel to OFF