Instruction Manual

22 Signal Connections
3.3
Origin Signal ORG
The origin signals (ORG1ORG4) are used as input signals for origin of the
mechanism. The following table lists the relative signal name, pin number,
and the axis number.
CN2 Pin No
Signal Name
Axis
#
41
ORG1
47
ORG2
91
ORG3
97
ORG4
The input circuits of the ORG signals are shown as following. Usually, a
limit switch is used to indicate the origin of one axis. The specifications of
the limit switches should with contact capacity of +24V, 6mA minimum. An
internal filter circuit is used to filter out the high frequency spike, which may
cause wrong operation.
EX+24V
I
f
=6mA Max.
Filter
Circuit
Motion ASIC
ORG
4.7K
EXGND
Inside PCI-8134/PCI-8134A
CN2
Switch
VDD
GND
Motor Encoder / Driver
With Open Collector Output
External Power for
Encoder
PCI-8134/PCI-8134A
A, B phase
signals
EA+, EB+,
EA-, EB-,
R