Owner's manual

Function Library 137
Visual Basic6 (Windows 2000/XP)
B_8154_set_pls_iptmode(ByVal AxisNo As Integer,
ByVal pls_iptmode As Integer, ByVal
pls_logic As Integer) As Integer
B_8154_set_pls_outmode(ByVal AxisNo As Integer,
ByVal pls_outmode As Integer) As Integer
B_8154_set_feedback_src(ByVal AxisNo As Integer,
ByVal Src As Integer) As Integer
@ Argument
AxisNo: Axis number designated to configure the pulse input/out-
put.
pls_iptmode: Encoder feedback pulse input mode setting (EA/
EB signals).
pls_logic: Logic of encoder feedback pulse.
card_id Physical axis AxisNo
0
00
11
22
33
1
04
15
……
Value Meaning
0 1X A/B
1 2X A/B
2 4X A/B
3 CW/CCW
Value Meaning
0 Not inverse direction
1 inverse direction