® E-ATX Dual Intel TRL-40 Xeon® E5 Series 4U Industrial Server User’s Manual Manual Rev.: 2.01 Revision Date: Aug. 15, 2014 Part No: 50-1X009-1010 Advance Technologies; Automate the World.
Revision History ii Revision Release Date 2.00 2014/5/9 2.
TRL-40 Preface Copyright 2014 ADLINK Technology, Inc. This document contains proprietary information protected by copyright. All rights are reserved. No part of this manual may be reproduced by any mechanical, electronic, or other means in any form without prior written permission of the manufacturer. Disclaimer The information in this document is subject to change without prior notice in order to improve reliability, design, and function and does not represent a commitment on the part of the manufacturer.
Conventions Take note of the following conventions used throughout this manual to make sure that users perform certain tasks and instructions properly. Additional information, aids, and tips that help users perform tasks. NOTE: CAUTION: WARNING: iv Information to prevent minor physical injury, component damage, data loss, and/or program corruption when trying to complete a task.
TRL-40 Table of Contents Preface .................................................................................... iii List of Figures ....................................................................... vii List of Tables.......................................................................... ix 1 Introduction ........................................................................ 1 1.1 Overview.............................................................................. 1 1.2 Features.......
This page intentionally left blank.
TRL-40 List of Figures Figure 1-1: Figure 1-2: Figure 1-3: Figure 1-4: Figure 1-5: Figure 1-6: Figure 1-7: Figure 1-8: Figure 1-9: TRL-40 Block Diagram .................................................... 7 TRL-40 Front View........................................................... 8 TRL-40 Rear View ........................................................... 9 TRL-40 Right Side View .................................................. 9 TRL-40 Left Side View................................................
This page intentionally left blank.
TRL-40 List of Tables Table 1-1: General Specifications..................................................... 5 Table 1-2: Rear I/O Panel Legend .................................................. 12 Table 1-3: TRL-40 Board Layout Legend .......................................
This page intentionally left blank.
TRL-40 1 Introduction 1.1 Overview The ADLINK TRL-40 is a 4U industrial server supporting the Intel® Xeon® Processor E5-2600 product family in a LGA2011 package, delivering a scalable high performance platform for a wide array of industrial applications. The TRL-40 supports 32/22nm dual CPUs at up to 2.4 GHz with integrated memory controllers and Direct Media Interface (DMI) connectivity to the Intel® C604 chipset.
1.2 Features 2 X 430 W x 176 H x 567 D mm (16.9 x 6.9 x 22.3")(w/o handles) X Supports dual Intel® Xeon® Processor E5-2600 series in LGA2011 package X Dual channel DDR3 1600 MHz memory for each CPU, up to a maximum of 128 GB in eight DIMM slots X Four PCIe x16 slots, one PCIe x8 slot, one PCIe x4 slot X One PCIe Mini Card slot support interface either mSATA or PCIe Gen2/USB2.
TRL-40 1.3 Specifications Product IPC System Model TRL-40 series Processor/System Intel® Xeon™ E5-2658, 2.1GHz, QPI 8GT/s, 20MB Cache, 32nm, 95W TDP, LGA2011(8C) Intel® Xeon™ E5-2648L, 1.8GHz, QPI 8GT/s, 20MB Cache, 32nm, 70W TDP, LGA2011(8C) Intel® Xeon™ E5-2620, 2.0GHz, QPI 7.2GT/s, 15MB Cache, 32nm, 95W TDP, LGA2011(6C) CPU Intel® Xeon™ E5-2658 v2, 2.4GHz, QPI 8GT/s, 25MB Cache, 22nm, 95W TDP, LGA2011(10C) Intel® Xeon™ E5-2648L v2, 1.
ASPEED AST2300 BMC IPMI v.2.0 AMI MegaRAC® web GUI. KVM/Media redirection support IPMI Support for remote power cycle, power down, power up and reset by NIC1 Serial over LAN (support by rear side COM port) HW monitor: +12V,+5V,+3.
TRL-40 Expansion Slots Slot 1: PCI Express x16 Gen3 from CPU1 Slot 2: PCI Express x16 Gen3 from CPU1 Slot 3: PCI Express x16 Gen3 from CPU2 Slot 4: PCI Express x8 Gen3 from CPU1 Slot 5: PCI Express x16 Gen3 from CPU2 Slot 6: PCI Express x4 Gen2 from PCH (physical PCIe x8 slot) Display Graphics BMC AST2300 built-in 64MB VRAM VGA Dsub-15 connector, up to 1920x1200 resolution@60 Hz Ethernet Controller Dual Intel® GbE controller I210-AT (NIC0 and NIC1) Interface PCI Express x1 bus Wake On LAN Yes Me
Model naming convention is as follows: TRL-40-AABBCCDEFFGHHH NOTE: Where: AA:CPU BB:RAM CC:HDD D:ODD E: Power supply FF:OS G: Accessory HHH:Reserved(000) Example:TRL-40-22080210001000 22:-Intel Xeon E5-2658 v2, 2.4GHz, QPI 8GT/s, 25MB Cache, 22nm, 95W TDP, LGA2011(10C)x2 08: ECC/REG 8Gx8 02:3.5" 1TB x2 1:slim ODD 0:600W Single 00:WO/OS 1: W/Swapbay 000: N/A.
TRL-40 1.4 Block Diagram SATA 3.0 x4 SATA RAID DDR3 1600 RDIMM DDR3 1600 RDIMM DDR3 1600 RDIMM DDR3 1600 RDIMM DDR3 1600 RDIMM DDR3 1600 RDIMM DDR3 1600 RDIMM DDR3 1600 RDIMM PCI-E x 2 QPI PCI-E x16 PCI-E x16 PCI-E x16 USB x1 PCI-E mini card (mSATA or PCIE) PCI-E x4 DMI x4 PCIE x1 MUX Intel I210AT PCI-E x1 WOL support RJ45 NC_SI SATA MUX SATA3.0 x1 PCI-E x1 Patsburg- B SATA3.
Intel® C604 Chipset The Intel® C600 Series chipset provides a connection point between various I/O components and Direct Media Interfacebased processors. Eight lanes of PCI Express Gen2 ports are supported. Dual-Channel DDR3 Memory The TRL-40 supports dual channel DDR3 1600 MT/s ECC registered or non-ECC unbuffered DIMMs up to 128GB total system memory in eight DIMM slots. Gigabit Ethernet Dual Intel® GbE I210-AT Controllers are connected from the Intel® C604 chipset.
TRL-40 10.3 7.1 101.6 465 Figure 1-3: TRL-40 Rear View 23 101 92.1 92.1 92.1 52.7 50 88 10#-32 16.
Figure 1-5: TRL-40 Left Side View Figure 1-6: TRL-40 Top View 10 Introduction
TRL-40 Figure 1-7: TRL-40 Underside View WARNING: The TRL-40 must be protected from static discharge and physical shock. Never remove any of the socketed parts except at a static-free workstation. Use the anti-static bag shipped with the product to handle the board. Wear a grounded wrist strap when installing and/or servicing. 1.
A VGA B RS-232/422/485 C 4x USB 2.0 D NIC0 E NIC1 Table 1-2: Rear I/O Panel Legend Serial Port Connector (COM1) Pin # 1 RS-232 DCD, Data Carrier Detect RS422 RS485 TXD- Data- 2 RXD, Receive Data TXD+ Data+ 3 TXD, Transmit Data RXD+ -- 4 DTR, Data Terminal Ready RXD- -- 5 GND, ground GND GND 6 DSR, Data Set Ready -- -- 7 RTS, Request to Send -- -- 8 CTS, Clear to Send -- -- 9 RI, Ring Indicator -- -- VGA Connector.
TRL-40 LAN Port (NIC0/1, RJ-45) Refer to the tables below for the LAN port pin and LED definitions. Pin # 10BASE-T/ 100BASE-TX 1000BASE-T 1 TX+ BI_DA+ 2 TX- BI_DA- 3 RX+ BI_DB+ 4 -- BI_DC+ 5 -- BI_DC- 6 RX- BI_DB- 7 -- BI_DD+ 8 -- BI_DD- LAN Status LED1 8 LED1 (left) Network link is not established or system power off LED2 1 LED2(right) OFF OFF 10 Mbps OFF Blinking 100 Mbps Green Blinking 1000 Mbps Orange Blinking NIC1 supports NCSI for IPMI v2.
1.
TRL-40 ATXPWR1 ATX Power Connector (24-pin) CLR-RTC1 Clear RTC Jumper CPU_FAN1/2 CPU Fan Connectors H_AUDIO1 Audio Daughter Board Header H_COM2 Serial Port Connector H_FRONT1 System Panel Pin Header H_USB1~2 USB 2.
1.
TRL-40 HD Audio Daughter Board Connector (H_AUDIO1) This connector is designed for use with the ADLINK DB-Audio2 daughter board. Pin # 1 2 9 10 Signal Function 1 GND Ground 2 AUD_BCLK 3 GND 4 ICH_AUD_SDIN1 5 P5V 6 ICH_AUD_SDOUT 7 P5V_AUD 8 P3V3_DVDD 3.
SATA Connectors Pin # Signal 1 GND 2 TXP 1 3 TXN 4 GND 5 RXN 6 RXP 7 GND 7 USB 2.0 Pin Headers (H_USB1~2) Pin # 1 Signal Pin # +5V Signal 2 +5V 3 USB0- 4 USB1- 5 USB0+ 6 USB1+ 7 GND 8 GND 9 Key 10 NC 1.10 Jumpers & Switches Clear RTC (CLR_RTC1) Clear BIOS settings and data/time.
TRL-40 Clear CMOS (JP1) Clear the BIOS settings. CMOS Status Connection Normal 1–2 Clear CMOS 2–3 JP1 Marvell SATA RAID Test Mode (JP2) For debug use.
BMC Console Port (JP3) Pin # Signal 1 VCC 3.3V 2 RX 3 TX 4 GND PCIe Mini-Card Function Selection (JP4/JP8) Status Connection mSATA 1–2 PCIe (default) 2–3 JP1 SATA1 Function Selection (JP5) Disable to use PCIe Mini-Card in mSATA mode.
TRL-40 Introduction 21
This page intentionally left blank.
TRL-40 2 Getting Started 2.1 Package Contents Before unpacking, check the shipping carton for any damage. If the shipping carton and/or contents are damaged, inform your dealer immediately. Retain the shipping carton and packing materials for inspection. Obtain authorization from the dealer before returning any product to ADLINK. X TRL-40 system server X Driver CD X Quick Start Guide 2.
XXX (where XXX is Sandy Bridge or Ivy Bridge). Follow the instructions given and reboot when instructed. 4. Install the Ethernet driver by running the program Autorun.exe from X:\IMBS90\LAN\513189_Release_17_4_OEM_Gene_284334 _split. Follow the instructions given and reboot if required. 5. Install the Marvel RAID driver by opening device manager. Navigate to the driver located in X:\IMB-S90\Marvell\PSP2.3.0.1046\windows\Driver\1.2.0.1032WHQL\storport\amd64.
TRL-40 Important Safety Instructions For user safety, please read and follow all instructions, WARNINGS, CAUTIONS, and NOTES marked in this manual and on the associated equipment before handling/operating the equipment.
X Never attempt to fix the equipment. Equipment should only be serviced by qualified personnel.
TRL-40 Getting Service Contact us should you require any service or assistance. ADLINK Technology, Inc. Address: 9F, No.166 Jian Yi Road, Zhonghe District New Taipei City 235, Taiwan ᄅؑקխࡉ৬ԫሁ 166 ᇆ 9 ᑔ Tel: +886-2-8226-5877 Fax: +886-2-8226-5717 Email: service@adlinktech.com Ampro ADLINK Technology, Inc. Address: 5215 Hellyer Avenue, #110 San Jose, CA 95138, USA Tel: +1-408-360-0200 Toll Free: +1-800-966-5200 (USA only) Fax: +1-408-360-0222 Email: info@adlinktech.com ADLINK Technology (China) Co., Ltd.
ADLINK Technology, Inc. (French Liaison Office) Address: 6 allée de Londres, Immeuble Ceylan 91940 Les Ulis, France Tel: +33 (0) 1 60 12 35 66 Fax: +33 (0) 1 60 12 35 66 Email: france@adlinktech.com ADLINK Technology Japan Corporation Address: ͱ101-0045 ᵅҀ䛑गҷ⬄ऎ⼲⬄䤯 ⬎ފ3-7-4 ⼲⬄ 374 ɛɳ 4F KANDA374 Bldg. 4F, 3-7-4 Kanda Kajicho, Chiyoda-ku, Tokyo 101-0045, Japan Tel: +81-3-4455-3722 Fax: +81-3-5209-6013 Email: japan@adlinktech.com ADLINK Technology, Inc.