XMC-E540 Dual-port 10GBASE-T Ethernet XMC module with Intel® Ethernet Controller X540 User’s Manual Manual Rev.: 2.00 Revision Date: August 7, 2013 Part No: 50-1Z124-1000 Advance Technologies; Automate the World.
Revision History Revision 2.
XMC-E540 Preface Copyright 2013 ADLINK Technology, Inc. This document contains proprietary information protected by copyright. All rights are reserved. No part of this manual may be reproduced by any mechanical, electronic, or other means in any form without prior written permission of the manufacturer.
Using this Manual Audience and Scope The XMC-E540 User’s Manual is intended for hardware technicians and systems operators with knowledge of installing, configuring and operating industrial grade computer systems. Manual Organization This manual is organized as follows: Chapter 1, Introduction: Introduces the XMC-E540, its features, block diagrams, and package contents. Chapter 2, Specifications: Presents detailed specification information.
XMC-E540 Conventions Take note of the following conventions used throughout this manual to make sure that users perform certain tasks and instructions properly. Additional information, aids, and tips that help users perform tasks. NOTE: CAUTION: WARNING: Preface Information to prevent minor physical injury, component damage, data loss, and/or program corruption when trying to complete a task.
This page intentionally left blank.
XMC-E540 Table of Contents Revision History...................................................................... ii Preface .................................................................................... iii List of Figures ........................................................................ ix List of Tables.......................................................................... xi 1 Introduction ........................................................................ 1 1.1 Overview..........
This page intentionally left blank.
XMC-E540 List of Figures Figure 1-1: XMC-E540 Functional Block Diagram ............................. 2 Figure 3-1: XMC-E540 Board Layout.................................................
This page intentionally left blank.
XMC-E540 List of Tables Table 2-1: XMC-E540 Power Consumption...................................... 7 Table 3-1: RJ-45 10GbE Connector Pin Definitions ....................... 10 Table 3-2: XMC Connector Pin Definition .......................................
This page intentionally left blank.
XMC-E540 1 Introduction 1.1 Overview The XMC-E540 is a dual-port 10GBASE-T Ethernet XMC module with equipped with an Inte® Ethernet Controller X540. Featured are dual RJ-45 copper ports supporting 10G/1000/100BASE-T with auto-negotiation, jumbo frames up to 15.5KB, TCP/UDP segmentation, IPv6 IP/TCP, IP/UDP receive checksum offload, FCoE Tx/Rx CRC offload, and 256KB FCoE transmit segmentation. The XMC-E540 is compliant with the VITA 42.3-2006 XMC PCI Express Protocol Layer Standard. 1.
1.
XMC-E540 1.4 Package Contents The XMC-E540 is packaged with the following components. If any of the items on the contents list are missing or damaged, retain the shipping carton and packing material and contact the dealer for inspection. Please obtain authorization before returning any product to ADLINK. The packing contents of the XMC-E540 are non-standard configurations and may vary depending on customer requests.
This page intentionally left blank.
XMC-E540 2 Specifications 2.1 XMC-E540 Module Standards VITA 42.3-2006 XMC PCI Express Protocol Layer Standard Form Factor • IEEE P1386, Standard XMC.3 • 74 mm x 149 mm x 8.2 mm (single width) Controller Intel® Ethernet Controller X540-AT2 • Dual port 100Mb/1000Mb/10Gb data rate • Intel® Virtualization Technology for Connectivity (VMDq, SR-IOV) • Fiber Channel over Ethernet • MACsec IEEE 802.
2.2 Intel® Ethernet Controller X540-AT2 The following section describes the features and functions of Intel® Ethernet Controller X540-AT2 6 X 10 GbE/1 GbE/100 Mb/s copper PHYs integrated on-chip X Support for jumbo frames of up to 15.5 KB X Flow control support: send/receive pause frames and receive X FIFO thresholds X Statistics for management and RMON X 802.
XMC-E540 2.3 Power Consumption The power consumption data of the XMC-E540 was measured installed in an ADLINK cPCI-6510 carrier blade using a Spirent SmartBits network performance analysis system. Power Consumption Engine Clock Current @ 5V Power (W) Idle Load 0.44 A 2.2 W Max. Load 1.50 A 7.
This page intentionally left blank.
XMC-E540 3 Board Interfaces This chapter illustrates the board layout, connector pin assignments, and switch settings to familiarize users with the XMC-E540. 3.
3.
XMC-E540 XMC Connector (CN1) A1 A19 F1 F19 Pin# A B C D E F 1 PET0p0 PET0n0 3.3V PET0p1 PET0n1 VPWR MRSTI# 2 GND GND Reserved GND GND 3 PET0p2 PET0n2 3.3V PET0p3 PET0n3 VPWR 4 GND GND Reserved GND GND Reserved 5 PET0p4 PET0n4 3.3V PET0p5 PET0n5 VPWR 6 GND GND Reserved GND GND NC 7 PET0p6 PET0n6 3.
This page intentionally left blank.
XMC-E540 4 Getting Started 4.1 Installing the Module 1. Remove the XMC slot filler faceplate from the front panel of the host board. 2. Insert the faceplate of the XMC module into the XMC slot in the front panel of the host board. 3. Carefully align the male connectors of the XMC module (component-side down) to the female connectors of the host board and firmly press down. 4. Secure the XMC module with the four screws provided from the bottom side of the host board.
4.2 Driver Installation The XMC-E540 drivers can be found on the ADLINK All-In-One DVD at X:\XMC\XMC-E540\LAN, or at the ADLINK website (http:/ /www.adlinktech.com). Driver installation procedures for Windows 7 are described below. 1. Install the Windows operating system before installing any driver. Most standard I/O device drivers are installed during Windows installation. 2. Install the LAN drivers by extracting and running the executable file in ...\LAN\Intel_Network_Adapter_AllOS_v16.6.
XMC-E540 Important Safety Instructions For user safety, please read and follow all instructions, WARNINGS, CAUTIONS, and NOTES marked in this manual and on the associated equipment before handling/operating the equipment. X Read these safety instructions carefully. X Keep this user’s manual for future reference. X Read the specifications section of this manual for detailed information on the operating environment of this equipment.
X Never attempt to fix the equipment. Equipment should only be serviced by qualified personnel. A Lithium-type battery may be provided for uninterrupted, backup or emergency power. WARNING: X 16 Risk of explosion if battery is replaced with one of an incorrect type. Dispose of used batteries appropriately.
XMC-E540 Getting Service Contact us should you require any service or assistance. ADLINK Technology, Inc. Address: 9F, No.166 Jian Yi Road, Zhonghe District New Taipei City 235, Taiwan ᄅؑקխࡉ৬ԫሁ 166 ᇆ 9 ᑔ Tel: +886-2-8226-5877 Fax: +886-2-8226-5717 Email: service@adlinktech.com Ampro ADLINK Technology, Inc. Address: 5215 Hellyer Avenue, #110, San Jose, CA 95138, USA Tel: +1-408-360-0200 Toll Free: +1-800-966-5200 (USA only) Fax: +1-408-360-0222 Email: info@adlinktech.com ADLINK Technology (China) Co.
ADLINK Technology, Inc. (French Liaison Office) Address: 15 rue Emile Baudot, 91300 Massy CEDEX, France Tel: +33 (0) 1 60 12 35 66 Fax: +33 (0) 1 60 12 35 66 Email: france@adlinktech.com ADLINK Technology Japan Corporation Address: ͱ101-0045 ᵅҀ䛑गҷ⬄ऎ⼲⬄䤯 ⬎ފ3-7-4 ⼲⬄ 374 ɛɳ 4F KANDA374 Bldg. 4F, 3-7-4 Kanda Kajicho, Chiyoda-ku, Tokyo 101-0045, Japan Tel: +81-3-4455-3722 Fax: +81-3-5209-6013 Email: japan@adlinktech.com ADLINK Technology, Inc.