WARNINGS
Do not store or use gasoline or other ammable vapors or liquids in the vicinity of this or any other equipment
Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury or death
Read the installation and maintenance instructions thoroughly before installing or servicing this equipment
Have the equipment installed by a quali ed installer in accordance with all federal, state and local codes
Do not install or use without all 4 legs
This equipment is for use in non-combustible locations only
Do not obstruct the ow of combustion and ventilation air
Do not spray controls or the outside of the equipment with liquids or cleaning agents
Allow for hot parts to cool before cleaning or moving
This equipment should only be used in a at, level position
Do not operate unattended
Any loose dirt or metal particles that are allowed to enter the gas lines on this equipment will damage the valve and
affect its operation
If you smell gas, follow the instructions provided by the gas supplier. Do not touch any electrical switch; do not try to
light the burner; do not use a telephone within close proximity.
TO INSTALL:
1. Remove unit from box and make sure all plastic, tape and packing materials are removed.
2. Place the unit on a at, secure surface with at least 12” of open space around all sides.
3. Install the feet onto the unit and make sure the unit is level
4. Check to make sure the outlet of the correct voltage for this item (120V) and gas connection is near. Do not use an
extension cord, this item must be plugged directly into an outlet.
5. Unit should be placed under a ventilation hood and their should be at least 2” of space between the back of the
oven and the wall. This will ensure proper air ow
The installation of this equipment must conform with local codes, or with the National Gas Code, ANSIZ223.1/NFPA 54,
or the Natural Gas and Propane Installation Code, CSA B149.1, as applicable.
The equipment and its individual shutoff valve must be disconnected from the gas supply piping system during any pres-
sure testing of that system at test pressures in excess of ½ psi (3.5 kPa).
The equipment must be isolated from the gas supply piping system by closing its individual manual shutoff valve during
any pressure testing of the gas supply piping system at test pressures equal to or less then ½ psi (3.5 kPa).
Clearance and positioning around the equipment:
This equipment must be installed adjacent to non-combustible surfaces only with a minimum spacing of 6” from all
sides. This equipment must be a distance of 6” from other equipment. The equipment must have the legs installed and
be placed on a non-combustible surface.
Air Supply and ventilation:
The area in front and around the equipment must be kept clear to avoid any obstruction of the ow of combustion and
ventilation air.
Adequate clearance must be maintained at all times in front of and at the sides of the equipment for servicing and
proper ventilation.
Pressure Regulator:
All commercial cooking equipment must have a pressure regulator on the incoming service line for safe and ef cient
operation. The regulator provided for this equipment is adaptable for both Natural gas and LP gas.
Regulator speci cations: ¾” NPT inlet and outlet, factory adjusted for 4” WC Natural Gas standard and may be
converted by quali ed personnel to be used for Propane at 10” WC.