User Manual Commercial Reach-In Refrigerators: RF-1D, RF-2D, RF-3D Commercial Reach-In Freezers: FZ-1D, FZ-2D This manual contains important information about your new Admiral Craft refrigerated unit. Please read this manual carefully before set-up, operation and maintenance.
INSTALLATION IMPORTANT!!! PLEASE READ BEFORE INSTALLATION 1. If the unit has recently been transported, do not use for a minimum of 24 hours before installing. 2. Make sure that the unit is at the desired temperature before loading it with product. 3. Ensure that the unit will have proper ventilation in the area that it will operate. 4. Inspect the unit to verify all accessories (shelves, shelf clips, casters) are equipped with the unit before proceeding with installation. 5.
SHELF BRACKET INSTALLATION Make sure to follow the diagrams listed below to install shelf brackets properly (picture of interior pilasters, right side) 1. Attach the back of the bracket first by sliding the opening (a) into the back pilaster 2.
SAFETY / WARNING 1. To minimize shock and fire hazards, be sure not to overload the outlet. One outlet should be designated to the unit only. 2. Do not use extension cords. 3. Do not put hands under the unity when moving. 4. When the unity is not being used for an extended period of time, unplug the unit from the outlet. 5. After unplugging the unit, wait at least 10 minutes before re-plugging it. Failure to wait the allotted time may cause damage to the compressor. 6.
REGULAR MAINTENANCE WARNING Disconnect power cord before cleaning any parts of the unit. CLEANING THE CONDENSOR COIL For efficient operation, it is important that the condenser surface be kept free of dust, dirt, and lint. It is highly recommended that the condenser coil be cleaned at least once a month. Clean with a commercial condenser coil cleaner and brush the condenser fins from top to bottom. After cleaning, straighten any bent fins with a fin comb.
TROUBLESHOOTING Before requesting any service on the unit, please check the following chart. Service calls resulting from lack of maintenance or misuse is not covered under the warranty and may also void the warranty. Please note that this guide serves only as a reference for solutions to common problems.
Troubleshooting Continued… SYMPTOM Cabinet temperature is too warm Cabinet is noisy POSSIBLE CAUSE Thermostat set too warm CORRECTIVE ACTION Set thermostat to lower temperature Blocked air flow Re-arrange products to allow proper air flow.
NOTES: RETAIN THIS MANUAL FOR FUTURE REFERENCE Please read the entire manual carefully before installing and operating. If certain recommended procedures are not followed, warranty claims will be denied. Notice: Admiral Craft reserves the right to make changes in design and specifications without prior notice.