Troubleshooting Continued…
SYMPTOM
POSSIBLE CAUSE
CORRECTIVE ACTION
Cabinet temperature is too
warm
Thermostat set too warm
Blocked air flow
Excessive amount of warm
products placed in the cabinet
Blown fuse or circuit breaker
tripped
Dirty condenser coil
Prolonged door open or door
left open
Evaporator coil iced over
Set thermostat to lower
temperature
Re-arrange products to allow
proper air flow. Make sure
there is at least four inches of
clearance from evaporator
Allow adequate time for
products to cool down
Replace fuse or reset circuit
breaker
Clean the condenser coil
Ensure doors are closed.
Avoid leaving the door open
for long periods of time
Unplug unit and allow coil to
defrost. Ensure that the
thermostat is not set to cold.
Ensure that the door gasket is
creating a proper seal.
Cabinet is noisy Loose parts
Tubing Vibration
Locate and tighten loose parts
Ensure tubing is free from
contact with other tubing or
components.