User's Manual

8
3.1.6.11 Color box packaged unit
shock test
Total cycles
Height
Floor condition
6 faces
2 edges
1 corner
65 cm
Plastic floor tile
3.1.6.12 Color box packaged unit
vibration test
Frequency
Force
Dwell time
Direction
Cycles
5 to 50 Hz
3.0 g
6 minutes each axis
3 axis vibration
10 cycles
3.1.7 Manufacturing Requirement
The objective is to drive the manufacturing cost down through fewer parts, higher volume, lower SMT cost,
higher yield and lower manufacturing overhead.
3.1.7.1 Design and Construction
The unit shall be designed with consumer grade parts and construction techniques.
3.1.7.2 Enclosures
The customer shall provide industrial design and tooling.
3.1.7.3 Labeling
3.1.7.3.1 Mouse Unit Labeling
Silkscreen of company logo on top of unit – Customer will provide silkscreen film and computer files.
Single sticker on bottom of unit – CUSTOMER will provide sticker film and computer files.
CUSTOMER shall provide the sticker material type. Sticker shall be serialized.
3.1.7.3.2 Base Unit Labeling
Silkscreen of company logo on top of unit – CUSTOMER will provide silkscreen film and computer
files.
Single sticker on bottom of unit – CUSTOMER will provide sticker film and computer files.
CUSTOMER shall provide the sticker material type. Sticker shall be serialized.
4.0 Quality Assurance Provisions
4.1 General Test Philosophy
Requirement verification shall be performed using the following methods:
Inspection – physical inspection of unit under test verifying compliance.
Test – measurement of specific design parameter and recording of measured results.
Design – compliance ensured by the nature of the design, verified by ensuring that the design includes
provisions for meeting that parameter.
5.0 Appendix