The mouse unit performance requirements are contained in the Table 2 below. Performance tests shall be
performed at 20 ± 5 °C (temperature) and 65 ± 10% (relative humidity).
Table 2. Mouse Unit Performance Requirements
Rqmt No. Parameter Description Value
3.1.1.2.2.1 Battery Type of battery 2 Alkaline AAA
(type 3)
3.1.1.2.2.2 Battery Expected life of battery
Operating conditions
- 4h/day
- 5d/week
- 15% usage
See Appendix 10
Target 4~ 6. months
3.1.1.2.2.3 Mouse key Operating force 50 ~ 75gf
3.1.1.2.2.4 Resolution 800 dpi
3.1.1.2.2.5 Tracking Tracking speed 400 mm/sec
3.1.1.2.2.6 Power Maximum
Standby
Sleep (wake-up by move mouse)
5 minutes before going into sleep
mode this will be revised based on
prototype testing of unit
30mA
0.7mA
0.2mA
3.1.1.2.2.7 Sensor Operating Temperature
Power supply Voltage
Clock Frequency CLK
ESD
SPEED
Reference plane to surface data sheet
0 ~40C
VDD: 3.0~3.6V
17.4, 18.432, 18.7 MHz
2KV
14 in/sec
3.1.1.2.2.8 Sensor Light
RED LED Light
output639nm
3.1.1.2.3 Base Unit Performance Requirements
The base unit performance requirements are contained in the Table 3 below.
Table 3. Receiver Performance Requirements
Rqmt No. Parameter Description Value
3.1.1.2.3.1 RF frequency Receive carrier frequencies 27MHZ
3.1.1.2.3.2 Receiver antenna
Antenna type Wired-loop antenna
integrated inside
housing
3.1.1.2.3.3 Receiver dynamic
range
Input signal level at receiver input port
Maximum (Damage level)
Minimum
+0dBm
-90dBm
3.1.1.2.3.4 Power:
USB Mode
Voltage range
Consumption less than 50mA in average
value
Consumption in suspend mode
(generic) less then 3mA in average
value
4.75V to 5.25VDC