3.1.3.2.1 Outline dimensions
Length
Width
Height
Maximum length
Maximum width
Maximum height
42mm
25mm
11mm
3.1.4 Maintainability
No maintainability shall be required for the base unit. The mouse unit shall use standard commercially
available batteries.
3.1.5 Environmental Conditions
The mouse and base units shall function over the following conditions. The unit will be used for indoor use.
Table 8. Environmental Conditions
Rqmt No. Parameter Description Value
3.1.5.1 Operating temperature
High
Low
No condensed
40 °C
0 °C
3.1.5.2 Storage temperature
High
Low
Battery not included in storage
temperature testing
60 °C
-10 °C
3.1.5.3 Relative humidity Maximum 85 %
3.1.6 Reliability
Reliability testing of the mouse unit shall be performed under the following conditions.
Table 9. Reliability Test
Rqmt No. Parameter Description Base Unit Value Mouse Unit Value
3.1.6.1 Mouse life test Load
Speed
Travel
Not applicable 100 gf vertical force
400 ± 40 mm/sec
300 miles in any
direction
3.1.6.2 Switch life test Switching speed
Operating force
Operating cycles
Not applicable 3 cycle/sec
100 ± 15 gf
1,000,000 cycles
3.1.6.3 High temperature test
After this test, mouse
shall be left at room
temperature for 1 hour,
relative humidity < 95%
Temperature
Storage time
65 ± 2 °C
96 hours
65 ± 2 °C
96 hours
3.1.6.4 Low temperature test
After this test, mouse
shall be left at room
temperature for 1 hour,
relative humidity < 95%
Temperature
Storage time
-15 ± 2 °C
96 hours
-15 ± 2 °C
96 hours
3.1.6.5 Moisture test
After this test, mouse
shall be left at room
temperature for 1 hour
Temperature
Relative humidity
Storage time
40 ± 2 °C
90 to 95%
96 hours
40 ± 2 °C
90 to 95%
96 hours