User's Manual
AdvancedRFTechnologies,Inc. 89
The“ULNoiseDet”buttonwilltakeyoutotheULNoiseDetectionpagewhichwillallowyoutoruntheULNoise
Detectionroutine.
Figure8‐46 ULNoiseDetection‐PCSband
The Auto UL noise measurement routine can be run by clicking on the Check button.After all
UL noise
measurement have been taken, the levels for each UL path will be displayed and along with the difference
betweenminimumdetectlevelandmeasureddetectlevel.
TheuserwillbeabletoseewhichpathisgeneratingtheelevatedULnoiselevelbasedonthemeasureddetect
leveland
differencevalue.
TonavigatebacktotheRFUcontrolpage,clickontheControltabagain.
8.2.3.3.4 ManualAttenControl
(Admin)(User)
Figure8‐47 ManualAttenuatorControlSetting(Control–RFU)
Table8‐15 DescriptionforMainGainControlSetting(Control–RFU)
Name Description Range Step AvailableAccounts
DownlinkAttenuator DownlinkAttenuatortobeadjustedmanually 0~25dB 0.5dB Administrator,User
UplinkAttenuator UplinkAttenuatortobeadjustedmanually 0~35dB 0.5dB Administrator,User
DLOutputALCLevel TosettheMaxoutputALClevel‐10~0dBm 0.5dBm Administrator
ULOutputALCLevel TosettheMaxoutputALClevel‐20~0dBm 0.5dBm Administrator,User