User's Manual
AdvancedRFTechnologies,Inc. 90
DLOutputALCOffset TosettheMaxoutputALCOffset‐10~0dBm 0.5dBm Administrator
ULOutputALCOffset TosettheMaxoutputALCOffset‐20~0dBm 0.5dBm Administrator
8.2.3.3.5 AlarmSetting
Figure8‐48 AlarmThresholdSetting(Control–RFU)
Table8‐16 DescriptionforAlarmThresholdSetting(Control–RFU)
Name Description Range
Default
threshold
DownlinkSignalLow
AllowstheusertospecifytheminimumincomingDLinputsignallevel
beforetriggeringa“DownlinkSignalLow”soft‐failalarm.
‐10~20dBm‐5dBm
DownlinkSignalNot
Detected
AllowstheusertospecifytheminimumincomingDLinputsignallevel
beforetriggeringa“DownlinkSignalNotDetected”soft‐failalarm.
‐10~20dBm‐10dBm
UplinkOverPower
Allowstheusertospecifythehowstrongtheoutputsignalofuplinkcan
bebeforetriggeringan“UplinkOverPower”HardFailalarm.
‐20~0dBm 0dBm