User's Manual
AdvancedRFTechnologies,Inc. 34
ADX‐H‐PSUhasthefollowingLEDsonthefrontpanelasshowninFigure3‐18.
P
O
W
E
R
C
H
G
S
T
S
L
O
W
B
A
T
T
A
C
F
A
I
L
D
C
F
A
I
L
Figure3‐18 HEPSULED
Table3‐4 HEPSULEDSpecifications
ADXDAS‐Module Specifications
Power SolidGreen ADX‐H‐PSUpowerisON
OFF ADX‐H‐PSUpowerisOFF
CHGSTS SolidYellow NoACpowerisavailableandADRF‐BBUisbeingused
BlinkingGreen PSUischargingtheADRF‐BBU
SolidGreen ADRF‐BBUiscompletelycharged
OFF Batteryisnotconnected
LOWBATT SolidYellow LowBatteryalarmexistinthePSU
SolidGreen NoLowBatteryalarmispresentinthePSU
ACFAIL SolidYellow ACFailalarmexistsinthePSU
SolidGreen NoACFailalarmispresentinthePSU
DCFAIL SolidYellow DCFailalarmexistsintheRFU
SolidGreen NoDCFailalarmsispresentinthePSU
3.1.5.2 ACInputOn /OffSwitch,ACInputPortandACInputSelectionSwitch
ON/OFFAC IN
AC SELECT
Figure3‐19 HEPSUACInputOn/OffSwitch,ACInputPortandACInputSelectionSwitch
TheAC Power on/off switchis located at the backpanel of HEPSU. The ADX‐H‐PSUcanoperate at110V AC
and220VAC.TheusershouldverifythattheAC
inputvoltageswitchissettothecorrectvoltagebeforepowering
ontheADX‐H‐PSU.
3.1.5.3 BatteryBackupPort,BatteryInstallPortandBatteryBackupSwitch
BATTERY
INSTALL
BATTERY
24V 1A
BATTERY
OFF
S/WOFF ON
Figure3‐20 BatteryBackupPort,BatteryInstallPortandBatteryBackupSwitch
TheBatterySwitchcanbeusedtoprovidepowertotheoptionalExternalBackupBattery(ADRF‐BBU)(Figure
3‐20).
The ADX‐H‐PSU can be connected to an ADRF‐BBU (ADRF Battery Backup Unit) which can
provide power
during a power outage.If an ADRF‐BBU is utilized, connect the ADRF‐BBU to the ADX‐H‐PSU via the external
batterybackupportasshowninFigure3‐20.