7.2 Commissioning
7.2.1 OpticCommissioning
Figure7‐4 ODUInstallpage
NavigatetotheInstallpageofADX‐H‐ODU(Figure7‐4)
Comparethe valuesofmeasuredoptic loss(LDpower–PDpower)intheWeb‐GUIwiththeactualopticloss
whichistypicallymeasured
atthetimeofinstallationofthefiber.
‐ ThecalculatedopticlossisdisplayedwhenthemousepointerisplacedovertheStatusindicator
ofeachlink
Figure7‐5 measuredopticlossdisplay
‐ If the difference betweenthe measure opticloss and the calculated loss islarger
than 1.5dBo,
thencleantheopticconnectorandopticportusingopticalcleaningswab.(refertosection6.4)
ThefollowingisthedefinitonoftheStatusindicatorofeachlink:
‐ Green:Indicatesthatopticlossislessthan5dBo
‐ Orange:Indicatesthatopticlossisgreaterthan
5dBo
‐ Gray:NoMasterHPRisconnectedtothislink.
ThefollowingisthedefinitionforthebackgroundcoloroftheCommissioningbutton:
‐ Green:Indicatesthatnoopticlosscompensationisneeded.
‐ Orange:Indicatesthatopticlosscompensationisneeded.
‐ Gray:NoMasterHPRisconnected
tothislink.
7.2.1.1 Howtocompensatetheopticloss