User's Manual

AdvancedRFTechnologies,Inc.  58
7.2 Commissioning
7.2.1 OpticCommissioning
Figure74 ODUInstallpage
NavigatetotheInstallpageofADXHODU(Figure74)
Comparethe valuesofmeasuredoptic loss(LDpowerPDpower)intheWebGUIwiththeactualopticloss
whichistypicallymeasured
atthetimeofinstallationofthefiber.
ThecalculatedopticlossisdisplayedwhenthemousepointerisplacedovertheStatusindicator
ofeachlink
Figure75 measuredopticlossdisplay
If the difference betweenthe measure opticloss and the calculated loss islarger
than 1.5dBo,
thencleantheopticconnectorandopticportusingopticalcleaningswab.(refertosection6.4)
ThefollowingisthedefinitonoftheStatusindicatorofeachlink:
Green:Indicatesthatopticlossislessthan5dBo
Orange:Indicatesthatopticlossisgreaterthan
5dBo
Gray:NoMasterHPRisconnectedtothislink.
ThefollowingisthedefinitionforthebackgroundcoloroftheCommissioningbutton:
Green:Indicatesthatnoopticlosscompensationisneeded.
Orange:Indicatesthatopticlosscompensationisneeded.
Gray:NoMasterHPRisconnected
tothislink.
7.2.1.1 Howtocompensatetheopticloss