7.2.2 HECommissioning
HEcommissioningiscomposedofHEBCUandHERFUcommissioning.TheHEBCUisanoptionalcomponent
andshouldbeusedwhenWPSs’signalsarebeingusedinthesamefrequencyband.
7.2.2.1 Compositepower
ToperformHEcommissioning, theusershouldcalculatedownlinkcomposite inputlevel
and add theproper
amountofbreathroomrequiredforriseintraffic.
Informationthatisneededtocalculatecommissioninglevelsare:
Servicefrequencyband
Servicetechnology
Thenumberofwirelessserviceprovider
Thenumberofcarrierspertechnology
Thenumberofbandsharing
sameamplifier
7.2.2.1.1 DLCompositeInputLevelCalculationsforHECommissioning
7.2.2.1.1.1 SingleWSPinafrequencyband
MeasuretheoutputpoweroftheBTSsignalthatwillbeinsertedintotheRFUusingaSpectrumAnalyzer.
If input signal includes more than one technology,then measure the composite
power of each
technology.
BasedonTable72,calculatethemaximumcompositeinputlevelbyusingthefollowingformula:
o “OutputpowerofBTSoftechnologybeingused”+“backoffvalue”(refertoTable72)
If calculated composite HE DL input power exceeds the permitted
maximum input range, then
additionalattenuationwillneedtobeaddedsothatthecalculatedHEDLinputpowerdoesnot
exceed25dBm.
Table72 Backoffvalueforeachtechnologyduetotrafficbreathing
Technology ConnectedtoBTS
CDMA 6~8dB
1xEVDO 6~8dB
WCDMA 8~10dB
HSPA 8~10dB
iDEN 0~3dB
GSM 0~3dB
LTE 8~10dB
7.2.2.1.1.2 MultipleWSPsinafrequencyband
When multiple WSPs exist in a frequency band at the same time, the ADXHBCU can be used to
combine/dividethesignalsreceivedfrommultipleWSPs.
TheADXHBCUcanreceiveupto3incomingDLsignals.Eachincomingsignal
canbeattenuated
individuallyallowingtheusertospecifypowerratiostocontrolthepowerpercarrier.
ThedownlinkpathofBCUhastheinputrangefrom0to25dBm.
IfthedownlinkoutputofBCUexceedsDLoutputALClevelsetbyuser,ALCfunctionwillactivate
and
limittheDLoutputfromexceedingthedefinedALClevel.
TheDLoutputofADXHBCUistransferredtotheDLinputofRFU.
MeasuretheoutputpoweroftheBTSsignalthatwillbeinsertedintotheBCUusingaSpectrumAnalyzer.
If input signal
includes morethan one technology, then measurethecompositepower of each
technology.
BasedonTable72,calculatethemaximumcompositeinputlevelbyusingthefollowingformula:
o “OutputpowerofBTSoft echnologybeingused”+“backoffvalue”(refertoTable72)