7.2.2.1.3 HEBCUCommissioning
When performing BCU commissioning, the user will need to enter the DL input commissioning level and
Targeted DL Output Power Ratio for eachRFpath.Refer to section 7.2.2.1 to calculateDL inputcommissioning
level.Ifaportisnotbeingused,theDLInputCommissioningLevel
shouldbesetto“disabled”.
7.2.2.1.3.1 HEBCUCommissioningProcedure
GotoInstallpageoftheBCUontheWeb‐GUI
Figure7‐6 BCUInstallWindow
SelectaDLInputCommissioningLevelforeachRFpath
‐ DLInputCommissioningLevelsrangeis0~+25dBm(0.5dBstep)
EnterHEBCUdownlinkoutputpowerratioforeachport
Pressthe“Apply”button
TheattenuationvalueandoutputALClevelforeachDL/ULpathwillbesetautomaticallybasedontheHEBCU
downlinkinputcommissioninglevelanddownlinkoutputpowerratioforeachport.
The
BCUwillchecktoseeifALCisactiveonanyoftheports.
‐ Duringthecommissioningroutine, if ALCisactivated,a popup messagewillappearstatingthat
ALC is running.If thisis the case, then thereis a chance thatthe “back‐off”value needs to
be
increasetoallowmorebreathingroom.
TheBCUcheckstoseeiftheBCUhasanyalarms.
‐ If a soft fail is present, the system will prompt the user whether or not they would like to
continue.
‐ Ifhardfailispresent,thecommissioningprocesswillstop
immediately.