User's Manual
AdvancedRFTechnologies,Inc. 65
7.2.2.1.4 HERFUcommissioning
IfaBCUisbeingusedinthesystem,theBCUshouldbecommissionedbeforecommissioningtheHERFU.
For RFU commissioning, the user will need to calculate the DL input commissioning level. Refer to section
7.2.2.1toforinformationtodeterminetheDLinputcommissioninglevel.
7.2.2.1.4.1 HERFUcommissioningProcedure
GotoInstallpageofRFUontheWeb‐GUI
Figure7‐7 RFUInstallWindow
EnterHERFUdownlinkinputcommissioninglevel
‐ Inputrange:0~+25dBm,0.5dBstep
Pressthe“Apply”button
Theattenuationlevelswillbesetautomatically
basedonDLInputCommissioningLevelthatisselected.
CheckstoseeifDLinputislow.
‐ During the commissioning routine, if DL input level is 10dB less than commissioning level, a
popupmessagewillappearstatingthatDLinputislow.Ifthisisthecase,thenthere
isachance
thatthe“back‐off”valueneedstodecreasebreathingroom.
CheckstoseeifALCisactive.
‐ Duringthecommissioningroutine, if ALCisactivated,a popup messagewillappearstatingthat
ALC is running.If thisis the case, then thereis a chance
thatthe “back‐off”value needs to be
increasetoallowmorebreathingroom.
CheckstoseeiftheRFUhasanyalarms.
‐ If a soft fail is present, the system will prompt the user whether or not they would like to
continue.
‐ Ifhardfailispresent,
thecommissioningprocesswillstopimmediately.
Commissioningissuccessfullycompleted.