User's Manual

AdvancedRFTechnologies,Inc.  73
8.2.2.1.4 HECommissioningStatus
DisplaycommissioningstatusofeachHEcomponent.
Figure89 HECommissioningstatus
Table86 DescriptionforHECommissioningstatus
Status Display Description
InstalledStatus
PhysicallyInstalled Textisblack
PhysicallyNotInstalled Textisgray
CommissioningStatus
Success Green
Failedornotcommissioned Gray
8.2.2.1.5 Alarm
Displaysalarm statusoftheNMS.Ifan alarmispresentin thesystem,the colorofthesystemalarmtabwill
changeaccordingtothetypeoffailure.
Table87 DescriptionforNMSalarm
Alarm Severity Description
System
OverTemperature
HardFail/
SoftFail
TemperatureofNMSishigherthanthethreshold
levelforovertemperaturealarm
UnderTemperature SoftFail
TemperatureoftheNMSislowerthanthethreshold
levelforundertemperaturealarm
SystemHalt HardFail HEsystemhalt
PowerAlarm
ACFail SoftFail ACpowerisoperatingoutsideofitsnormalrange
DCFail SoftFail DCpowerisoperatingoutsideofitsnormalrange
OverCurrent HardFail
TotalcurrentofHEishigherthanthethresholdlevel
forovercurrentalarm
BatteryLow SoftFail
VoltageofbatteryconnectedtoHEPSUislowerthan
thedefinedthreshold
