User's Manual

AdvancedRFTechnologies,Inc.  89
The“ULNoiseDetbuttonwilltakeyoutotheULNoiseDetectionpagewhichwillallowyoutoruntheULNoise
Detectionroutine.
Figure846 ULNoiseDetection‐PCSband
The Auto UL noise measurement routine can be run by clicking on the Check button.After all
UL noise
measurement have been taken, the levels for each UL path will be displayed and along with the difference
betweenminimumdetectlevelandmeasureddetectlevel.
TheuserwillbeabletoseewhichpathisgeneratingtheelevatedULnoiselevelbasedonthemeasureddetect
leveland
differencevalue.
TonavigatebacktotheRFUcontrolpage,clickontheControltabagain.
8.2.3.3.4 ManualAttenControl
 
(Admin)(User)
Figure847 ManualAttenuatorControlSetting(ControlRFU)
Table815 DescriptionforMainGainControlSetting(ControlRFU)
Name Description Range Step AvailableAccounts
DownlinkAttenuator DownlinkAttenuatortobeadjustedmanually 0~25dB 0.5dB Administrator,User
UplinkAttenuator UplinkAttenuatortobeadjustedmanually 0~35dB 0.5dB Administrator,User
DLOutputALCLevel TosettheMaxoutputALClevel‐10~0dBm 0.5dBm Administrator
ULOutputALCLevel TosettheMaxoutputALClevel‐20~0dBm 0.5dBm Administrator,User