7.1.6 BOM Comparison & Check Band Configuration
x BOM comparison
- On the System information page in the System menu, the list of all components connected to the
ADX-H-NMS should match the ADX Navigation tree. This list can be used to verify BOM generated
by designer or installer for all active components. Please note that passive components such as
the ADX-H-CHC, ADX-R-CHC, ADX-H-PSU, and the ADX-R-4WS will not show up on this report.
x Check Band Configuration
- Check whether the band configuration of ADX-H-RFU is identical to the band configuration of the
ADX HRU units. Any discrepancies will appear in the System Information report.
- Check to see if there are multiple remote modules with the same frequency bands within 1
remote unit. This information is displayed on the System Information page in the System menu
as notification message.
7.1.7 Lock current navigation tree
x If there are no errors in the process of BOM Comparison & Check Band Configuration, then lock the Navigation
Tree by cliking on the “Lock System” button.
- After locking the Navigation Tree, link fail alarms should not appear. If link fail alarms are
present, please check the physical connection of the device with the link fail alarm.
- The system must first be placed in the “Unlock” state before adding any new devices. Newly
added devices will appear in the Navigation Tree when the page is refreshed. Once all new
hardware has been added to the Navigation Tree, the tree must be locked before commissioning