7.3 DAS Install Verification
7.3.1 Setting SNMP & Remote IP
x Go to Install page of NMS (refer to section 8.2.4.1.4)
x When external modem box is connected, user should set SNMP & Remote IP information.
7.3.2 Verification through Web based GUI
x Go to System information page of System (refer to section 8.2.5.4.1)
- Check if Remote Module with same frequency band exist more than one within one HRU.
- Check if there are any noncommissioned modules in HE or RU.
- Check if any critical alarms are present.
7.3.3 UL noise power detection
When the UL noise levels is larger than the expected value, ADX DAS has a function that will measure the
uplink noise for each HRU and will generates a report with the UL noise levels. This will help the user determine
which HRU might be the cause of the elevated UL noise.
x UL noise power measurement can be performed for only one frequency band at a time.
x For more information, refer to section 8.2.3.3.3.