Table 8-5 System Summary Description
Parameters Description
Connected Display the number of modules physically connected to ADX DAS
Soft Fail Display the number of soft fail present on each module
Hard Fail Display the number of hard fail present on each module
Link Fail Display the number of link fail present on each module
Not Commissioned
Display the number of non-commissioned or commission failed module
Commissioned Display the number of successfully commissioned module
8.2.2.1.2 HE View / HRU View, System Scan Time
x HE View/RU View
- Displays whether the NMS is set to HE view or HRU view.
- Refer to section 3.1.1.4
x System Scan Time
- Displays the time it takes to scan and update the information of all the modules that are on the
navigation tree. This time will increase as more components are added to the system.
- When Navigation Tree is unlocked, the user should wait at least the “System Scan Time” for the
system to detect newly added hardware.
Figure 8-7 System scan time, HE view/RU view
8.2.2.1.3 HE Alarm Status
Display the alarm status of each HE component.
Figure 8-8 HE alarm status