x DL Input: Displays the currently incoming signal strength of each RF path along with the composite DL
input power of all 3 RF paths.
x Atten: Displays the attenuation values that the system is currently using which is defined by the
power ratios specified by the user.
x DL Output: Displays the output value for each RF path along with the composite DL output power of
all 3 RF paths. The DL Output level for each RF path will not exceed 5dBm and the composite output
power will not exceed 10 dBm.
8.2.2.2.3 Power Ratio
Figure 8-13 Status BCU Power Ratio
x Targeted DL Output Power: Displays desired power ratios specified by the user. If unit has not been
commissioned, “Not Commissioned” will be displayed.
x Actual DL Output Power: Displays the currently power ratios that the system is using. These values
will fluctuate based on the amount of traffic that is in the system.
8.2.2.2.4 Alarm
Displays the current alarm status of each individual RF path. Parameters for both DL Signal Low and DL Input
Overload can be specified from the Control tab.
Figure 8-14 Status BCU Alarm