User's Manual

Advanced RF Technologies, Inc.
90
The “UL Noise Det” button will take you to the UL Noise Detection page which will allow you to run the UL Noise
Detection routine.
Figure 8-46 UL Noise Detection - PCS band
The Auto UL noise measurement routine can be run by clicking on the Check button. After all UL noise
measurement have been taken, the levels for each UL path will be displayed and along with the difference
between minimum detect level and measured detect level.
The user will be able to see which path is generating the elevated UL noise level based on the measured detect
level and difference value.
To navigate back to the RFU control page, click on the Control tab again.
8.2.3.3.4 Manual Atten Control
(Admin) (User)
Figure 8-47 Manual Attenuator Control Setting (Control RFU)
Table 8-15 Description for Main Gain Control Setting (Control RFU)
Name Description Range Step Available Accounts
Downlink Atten
Downlink Attenuator to be adjusted manually
0 ~ 25dB
0.5dB
Administrator, User
Uplink Atten
Uplink Attenuator to be adjusted manually
0 ~ 35dB
0.5dB
Administrator, User
DL Output ALC Level
To set the Max output ALC level
-10 ~ 0dBm
0.5dBm
Administrator
UL Output ALC Level
To set the Max output ALC level
-20 ~ 0dBm
0.5dBm
Administrator, User