User's Manual Part 1
AdvancedRFTechnologies,Inc. 14
1. INTRODUCTION
Upto(8)frequencybandsinonebody:CurrentlytheADXsupports700MHz(LowerA,LowerB,LowerC,and
UpperC),700MHzPublicSafetyw/UpperDsupport,Cellular,PCS,SMR800/SMR900,andAWSbands.
1.1 Highlights
ModularStructure
‐ Supportsmultibandsservice(700MHz,700MHz
PS,Cell,PCS,AWS,SMR800/SMR900etc.)inonebody
‐ Supportsupto8RFunits
Supportsoptionalcombining/balancingofmultiplecarriers’signalsviaBCU(BandCombinerUnit)
Supportsuptoaofmaximumof32SISORemoteUnits
30dBmofdownlinkcompositeoutputpower
o 33dBm
availableforPCSandAWS
Requiresonlysinglestrandoffiberperremoteunit
Operateswithupto5dBoopticalloss(Singlemode)
SupportsSNMPv1,v2,v3(get,set&traps)
Web‐basedGUIInterface;No3rdpartyGUIsoftwarerequired
Web‐GUIconnectivityvia
DHCPinhostmode
VersatilityandUsability:ADX givestotalcontrol totheuser.Controlparameterssuchasgain,outputpower,
andalarmthresholdcanbechangedusingWeb‐GUIinterfaceallowingtheusertofinetunethesystemtothe
givenRFenvironment.
Uplinknoisemeasurementroutine
SupportRUViewmode,refertosection3.1.1.4
Incremental Automatic Shutdown/Resume Time: ADX gradually increases the time span between automatic
shutdownandresumeperiodbeforeitpermanentlyshutsitselfdown
SupportALCfunctiontopreventADXDASfrominputoverloadoroutputoverpower