User's Manual Part 2

AdvancedRFTechnologies,Inc.  72
DLCommissioningLevel:DisplaysthecommissioninglevelforeachindividualRFpath.Ifunithasnot
beencommissioned,“NotCommissioned”willbedisplayed.
DLInput:DisplaysthecurrentlyincomingsignalstrengthofeachRFpathalongwiththecompositeDL
inputpowerofall3RFpaths.
Atten: Displays the attenuation values that the system is currently using which is defined by the
powerratiosspecifiedbytheuser.
DLOutput:Displaystheoutputvalueforeach RFpathalongwiththecompositeDLoutputpowerof
all3RFpaths.TheDLOutputlevel
foreachRFpathwillnotexceed5dBmandthecompositeoutput
powerwillnotexceed10dBm.
8.2.2.2.3 PowerRatio
Figure813 StatusBCUPowerRatio
TargetedDLOutputPower:Displaysdesiredpowerratiosspecifiedbytheuser.Ifunithasnotbeen
commissioned,“NotCommissioned”
willbedisplayed.
Actual DL Output Power: Displays thecurrently power ratiosthat the systemisusing.These values
willfluctuatebasedontheamountoftrafficthatisinthesystem.
8.2.2.2.4 Alarm
DisplaysthecurrentalarmstatusofeachindividualRFpath.ParametersforbothDLSignal
LowandDLInput
OverloadcanbespecifiedfromtheControltab.
Figure814 StatusBCUAlarm