User's Manual Part 2

AdvancedRFTechnologies,Inc.  74
Figure818 Power&GainDisplay(User)
Input[dBm]: DisplaystheDownlink RF inputlevelwhichcomesfromtheADXHBCU, BTS.Thisvalueshould
bebetween0to25dBm.
ALCAtten[dB]:Theamountofattenuationthatisbeingusedbythesystemwhen
ALCisactive.
Atten[dB]:Theamountofattenuationthathasbeensetmanuallybytheuser.
Output[dBm]:Thedownlink/uplinkoutputpoweroftheRFUandNOTtheoutputpoweroftheRU.
8.2.2.3.3 Alarm
Displays System, RF, and Power Alarms.If an alarm is present in the
system, then the color of the tab will
changeaccordingtothetypeoffailure.
Table88 RFUAlarmStatus
Alarm Severity Description
System
LinkFail SoftFail
Acomponentisphysicallyconnected,butthe
NMSisunabletocommunicatewithit.
OverTemperature
HardFail/
SoftFail
ThetemperatureofNMSishigherthanthe
thresholdlevelforovertemperaturealarm.
UnderTemperature SoftFail
ThetemperatureofNMSislowerthanthe
thresholdlevelforundertemperaturealarm.
SystemHalt HardFail
Systemwillgointoa“SystemHalt”statewhena
hardfailalarmdoesnotclearafter10checks.
SystemHaltcanonlybeclearedwithapower
cycle,reboot,orfactorysettings.
RFAlarm
DLSignalnotdetected SoftFail
Downlink inputsignal islowerthanthedefined
thresholdbyuser.
DLSignalLow SoftFail
Downlinkinputsignal islowerthanthedefined
thresholdbyuser.
InputOverload
HardFail/
SoftFail
Downlinkinputsignal ishigherthanthedefined
threshold.
Overpower
HardFail/
SoftFail
Uplinkoutputsignalishigherthanthedefined
thresholdbyuser.
PowerAlarm
ACFail SoftFail ACpowerisnotoperatingwithinparameters.
DCFail SoftFail DCpowerisnotoperatingwithinparameters.
OverCurrent HardFail
TotalcurrentofHEishigherthanthethreshold
levelforovercurrentalarm.
BatteryLow SoftFail
VoltageofbatteryconnectedtoHEPSUislower
thanthedefinedthreshold.