User's Manual Part 2
AdvancedRFTechnologies,Inc. 81
8.2.2.6.3 OpticPower(Master‐RUOnly)
DisplaytheLDPowerandPDPowerofopticmoduleinsidetheMasterRU.
Figure8‐32 OpticPower(Status–MasterRUonly)
8.2.2.6.4 OperatingStatus
Table8‐13 OperatingStatus(Status–RemoteModule)
Alarm Severity Description
System LinkFail SoftFail NocommunicationwithNMS.
OverTemperature
HardFail
/SoftFail
Temperature ishigherthanthethresholdlevelfor
overtemperaturealarm.
Under
Temperature
SoftFail
Temperatureislowerthanthethresholdlevelfor
undertemperaturealarm.
SystemHalt HardFail
SystemhaltoneithertheMasterRUorSlaveRU.
Systemhaltoccurswhenahardfailalarmfailsto
clearafter10checks.
ORULDFail SoftFail LDFailpresentintheMasterRU’sopticunit.
ORUPDFail SoftFail PDFailpresentintheMasterRU’sopticunit.
RFAlarm
InputOverload HardFail
Uplinkinputsignalishigherthanthedefined
threshold.
OverPower
HardFail
/SoftFail
Downlinkoutputsignalishigherthanthedefined
thresholdbyuser.
VSWR SoftFail
Triggeredwhenpowerisbeingreflectedbackto
thesystem,typicallyduetoalooseconnector.
PowerAlarm
ACFail SoftFail ACpowerisnotoperatingwithinparameters.
DCFail SoftFail DCpowerisnotoperatingwithinparameters.
OverCurrent HardFail
TotalcurrentofRUishigherthanthethreshold
levelforovercurrentalarm.
BatteryLow SoftFail
VoltageofbatteryconnectedtoHEPSUislower
thanthedefinedthreshold.