6.2.2 RU Installation Procedure
CAUTION: ADX DAS RU should be installed inside building only.
6.2.2.1 Installing a ADX DAS RU in a rack
If the ADX RU chassis is being wall mounted then allow clearance of 3” (76mm) front and rear, and 2” (51mm)
on both sides for air circulation. No top or bottom clearance is required.
When ADX DAS RU mounts in a standard 19 equipment rack, rack or wall type fan is needed for heat
dissipation. The rack type fan (ADX-R-FAN) must have at least 1.75" of clearance.
x Consideration:
- Eight mounting holes are located on 4 corners of ADX RU to attach it to the 19” rack. The ADX RU must be
securely attached to support the weight of the ADX-RU units.
x Mount procedure
- The following steps should be followed while mounting the ADX-RU units
! Detach the wall mount bracket located at the base of the ADX-RU chassis
! Verify that the RU and Mounting hole are in good condition
! Screw the ADX DAS RU to the 19”rack
! Make sure the ADX RU is securely attached
! Connect the GND cable
! Connect the RF cable
! Connect the Power
! Connect the Optic cable