User's Manual

Advanced RF Technologies, Inc.
89
8.2.3.6 Control Remote Module (Master or Slave RU)
Figure 8-54 Control Remote Module
8.2.3.6.1 General Setting (Admin/User)
(Admin) (User)
Figure 8-55 General Setting (Control - RU)
Table 8-18 Description for General Setting (Control - RU)
Name Description Available Accounts
Downlink ALC
This setting allows you to enable or disable the downlink ALC function. When
ALC is enabled, the
downlink output power will not exceed the Downlink
Output Level specified in the Manual Atten Control section.
Administrator
Downlink On
This setting allows you to enable or disable the Downlink path.
Administrator, User
Uplink ALC
This setting allows you to enable or disable the uplink ALC function. When ALC
is enabled, the
Uplink output power will not exceed the Uplink Output Level
specified in the Manual Atten Control section.
Administrator
Uplink On
This setting allows you to enable or disable the Uplink path.
Administrator, User