User's Manual Part 3

Advanced RF Technologies, Inc.
81
8.2.2.6.3 Optic Power (Master-RU Only)
Display the LD Power and PD Power of optic module inside the Master RU.
Figure 8-32 Optic Power (Status Master RU only)
8.2.2.6.4 Operating Status
Table 8-13 Operating Status (Status Remote Module)
Alarm
Severity
Description
System
Link Fail
Soft Fail
No communication with NMS.
Over Temperature
Hard Fail
/ Soft Fail
Temperature is higher than the threshold level for
over temperature alarm.
Under
Temperature
Soft Fail
Temperature is lower than the threshold level for
under temperature alarm.
System Halt
Hard Fail
System halt on either the Master RU or Slave RU.
System halt occurs when a hard fail alarm fails to
clear after 10 checks.
ORU LD Fail
Soft Fail
LD Fail present in the Master RU’s optic unit.
ORU PD Fail
Soft Fail
PD Fail present in the Master RU’s optic unit.
RF Alarm
Input Overload
Hard Fail
Uplink input signal is higher than the defined
threshold.
Over Power
Hard Fail
/ Soft Fail
Downlink output signal is higher than the defined
threshold by user.
VSWR
Soft Fail
Triggered when power is being reflected back to
the system, typically due to a loose connector.
Power Alarm
AC Fail
Soft Fail
AC power is not operating within parameters.
DC Fail
Soft Fail
DC power is not operating within parameters.
Over Current
Hard Fail
Total current of RU is higher than the threshold
level for over current alarm.
Battery Low
Soft Fail
Voltage of battery connected to HE PSU is lower
than the defined threshold.