Advanced RF Technologies, Inc.
31
WARNING: Inserting a CW signal into the AXM700FB-9543-ICS-XP when ICS is enabled will cause the system to
generate a false alarm. The false alarm will cause the system to go into a shutdown state. If a CW signal
needs to be injected into the repeater for testing purposes, the ICS routine must be turned off.
5.3.2 System
Figure 5-10 System
• Reboot: Clicking the reboot button will have the following popup show up:
Figure 5-11 Pop-up message when Reboot button is pressed
Click OK to reboot the repeater or click Cancel to exit out
• Factory Setting: Resets the repeater to the original factory settings
Figure 5-12 Pop-up message when Factory Setting button is pressed
5.3.3 SNMP Trap
Figure 5-13 SNMP Trap
• SNMP Trap ON – Enables or Disables SNMP traps from being sent out when an alarm is triggered.
• Heartbeat Periodic Time [min] – Specifies the amount time between heartbeats
5.3.4 Manual Gain Control
Figure 5-14 Manual Gain Control Setting
• Downlink Gain/Uplink Gain: Allows the UL gain to be adjusted manually when ALC is OFF