User's Manual

Table Of Contents
Advanced RF Technologies, Inc.
17
2. OVERVIEW
2.1 LED
PSR-78-9533 LED indicator lights are located on the inside of the repeater towards the bottom. Below the LED
indicators is a button that is used to trigger the door open alarm.
Figure 2-1 LED Panel
Table 2-1 LED Specifications
POWER
DL
UL
ALARM
AC Fail
DL Signal Not Detected
UL Out-Band Overload
Power Related Alarms
DC Fail
DL Signal Low Detected
UL Input Overload
RF DL Path Related Alarms
Battery Fail
DL RF Power
UL DSP Over Input
RF UL Path Related Alarms
Low Battery
DL Out-Band Overload
UL Over Input
Over Temperature
Battery Not Charge
DL Input Overload
UL Over Power
DSP Communication
Battery Not Connected
DL DSP Over Input
UL Return Power
Door Open
Over Current
DL Over Input
UL PLL Fail
System Halt
DL Over Power
DL Return Power
DL PLL Fail
LED Indicator Specifications
Solid Green
Normal operation
Solid Yellow
Soft Fail alarm exists in the system
Solid Red
Hard Fail alarm exists in the system
2.2 Host / Remote Switch
The Host/Remote Switch allows the user to switch the default Repeater IP, Subnet Mask, and Gateway of the
Ethernet port of the repeater to an alternative setup. These settings can only be adjusted by logging into the
repeater under HOST mode and configuring the settings under the Modem Box Setting section on the Install
Page (section 5.4.6).
Once the settings are set, flipping the switch to the REMOTE position will reboot the repeater with the new
alternate settings. Please note that when the repeater is set to the REMOTE position, DHCP is disabled and the
repeater will not automatically assign an IP address to any device that connects directly to the repeater.
Host IP: 192.168.63.1 (Fixed IP, unable to modify this IP address)
Remote IP: 192.168.63.5 (Default IP, but can be modified in Host mode)
Figure 2-2 Host/Remote Switch