Advanced RF Technologies, Inc.
22
2.3.5 Grounding
A ground cable is included in the box. The grounding terminal is located at the lower right-hand side of the BDA.
The grounding cable should be properly connected before powering on the equipment.
Figure 2-9 Ground Cable Terminal
Ground terminals located on the side of the repeater and can support a ground cable up to 1.25mm² (16AWG)
in diameter and should be permanently connected to a grounding bar.
2.3.6 Ethernet Port
The GUI port can be used to communicate directly with the PSR-78-9533 using an RJ-45 crossover cable. The
weatherproof cap must first be unscrewed to gain access to the GUI port.
Figure 2-10 Ethernet Port