DL RF Power
Input + gain does not match the output level.
(default delta of 6 dB)
Overpower
Output level is above the max output levels.
AGC On case (Soft: AGC Level + 1~2dB, Hard: AGC Level + >2dB)
AGC Off case (Soft: max output level + 1~2dB, Hard: max output
level + >2dB)
VSWR
Power is being reflected back to the repeater. Threshold = output
power - 8dB. For example, if the repeater is outputting 24dBm and
detects 16dBm of return power, then the VSWR will be triggered.
(Alarm will only trigger when output power is 15dBm or greater)
Door
Door alarm set: Door open
Door alarm clear: Door close
3.3 External Alarms
The PSR-78-9533 supports dry contact alarms and can be connected to a fire alarm control panel. The user can program the
repeater to either create an open or closed circuit when an alarm is present in the system.
3.3.1 External Alarm Output interface
Simplex Alarm Box
Simplex
Digital Board
24V dc
ADRF PSR Repeater
ADRF
Digital Board
External Alarm Name
Set Condition
Fire Alarm
Donor Antenna Malfunction
- UL Return Power Hard Fail or No DL Signal Detected
Active RF Device Malfunction
- DL Return Power Hard Fail
- DL/UL Over Power Hard Fail
- DL/UL Input Overload Hard Fail
Low Battery Capacity (70% depleted)
- Low Battery Soft Fail
System Component Malfunction
- Over Current Hard Fail
- Over Temperature Hard Fail
- DSP Hard Fail
- Out-band Overload Hard Fail
System Monitoring
Normal AC Power
- AC Normal Set
- AC Fail Soft Clear
Loss of Normal AC Power
- AC Fail Soft Set
- AC Normal Clear
Battery Charger Failure
- Battery Fail Soft Fail
- Battery Not Connected Soft fail
- Battery Not Charge Soft Fail
Low Battery Capacity (70% depleted)
- Low Battery Soft Fail
Donor Antenna Malfunction
- UL Return Power Hard Fail
Active RF Emitting Device Malfunction
- RF Power Soft Fail