8. SPECIFICATIONS
8.1 Electrical Specifications
Table 8-1 Electrical Specifications
Parameters
Specifications
Remarks
DL UL
Frequency Range
(MHz)
FirstNet + PS 700
758 - 775MHz(For FCC)
(768-769MHzGuard band)
768775 (For ISED)
788 - 805 MHz(For FCC)
(798- 799MHz Guard band)
798 - 805(For ISED)
PS 800 851 - 861 806 - 816
Composite Output
Power
FirstNet / PS 700 /
FirstNet + PS 700
33 dBm 30 dBm
PS 800 33 dBm 30 dBm
FirstNet + PS 700 +
PS 800
36 dBm
(33dBm + 33dBm)
30 dBm
System Gain (dB) 95 95
Filter selection Broad / Narrow / Broad + Narrow band
Simultaneous Filter
Support numbers
Broad Band
2 (non-contiguous) @ FirstNet / PS 700 / PS 800 / FirstNet
+ PS 700 / FirstNet + PS 700 + PS 800
Narrow Band
Up to 16 (Non-contiguous) @ PS 700 / PS 800
Up to 32 (Non-contiguous) @ PS 700 + PS 800
Filter Bandwidth
Broad (MHz) 5, 10MHz
Extra filter upload available by
custom request.
Narrow (KHz) 6.25 ~75 (6.25 x n , n= 1~12)
Filter Roll-off
Broad (MHz) 60dBc@Filter Bandwidth Edge + 1MHz
Narrow (KHz) 55dBc @Filter Bandwidth Edge + 3 * Filter BW
Spurious FCC Rule Compliant
Passband Ripple ±2 dB
ALC Dynamic Range ≥ 60dB
Gain Dynamic Range ≥ 45dB
Channel Setting Resolution 0.025 kHz
Noise Figure @ Max. gain ≤5dB
System
Group Delay
Broad Band <6us
Narrow Band
<126us@6.25KHz BW, <67us@12.5KHz BW, <36us@25KHz
BW, <10us@200KHz BW
Power Supply 100 -240 VAC, 60 Hz (Free Voltage) Optional battery backup
Power Consumption
150 W
Max RF Input Power without over drive -20dBm
No damage Max Input Power +10 dBm
Impedance 50 Ω
VSWR
1.3 : 1
Dry Contacts NFPA 1221 2016 Code Compliant
Remote Alarming /
Network Management
Dry Contacts, Web-GUI, SNMP, SNMP-Traps (External
Wireless Modem Required)
Humidity 5% - 90% RH Condensed