15 fps option for this parameter. If the location is downstream
from a pump station and displays rapid changes in velocity
from reading to reading, ADS also re commends changing the
Ma ximum Ve locity setting from Auto to a setting slightly
above the maximum recorded velocity.
Transmit Fr equency Select the frequency at which to
transmit the signal. ADS recommend s leaving the default
setting (High) selected.
Gain This value represents the factor ap plied to raw velocity
(RAWVEL entity in Qstart) to determine aver age velocity and
to calculate quantity for the Flow 1(2) device. Qstart does not
apply Gain to the velocity readings rep orted in Diagnostics,
where the raw velocity readings are used for comparison
against the manual measurements.
Cross Check Gain Enter t he value by which to multiply raw
velocity readings in the monitor to determine average velocity
for comparison purposes in the monitor.
Store D ata Se le c t this checkbox to ensure the monitor logs
the velocity data to memory. This option is selected by default.
Advanced Select this button to ac c e ss the Advanced
Parameters dialog.
Advanced P ar ameters dialog