Configura tion and Activation 6-31
Advanced P ar ameters dialog
Note: Modifications made to the Ad vanced Parameters
should be performed only by or under the guidance of
trained ADS personnel. Therefore, ADS r eco mmends
leaving the default settings (Auto) in place.
Modify the parameter s as necessary, and then select OK once
complete.
DAC Gain Choose the method for managing the
amplification of the analog signal that returns to the sensor:
Auto Select this op tion to allow the monitor to
automatically optimize the amplification of the signal.
Manual Select this option to e nter a fixed value
between -12db (lower amplification) and +12db (high
amplification) at which to amplify the signal.
Surcharge Detection Select the Disable checkbox to
prevent the monitor from impleme nting the Surcharge
Detection funct ion when processing smart dep th data. For
locations that typically do not experience surcharges,
disabling Surcharge Detection eliminates the processing
time required for this function and, as a result, conserves
monitor power.