User Manual

Configura tion and Activation 6-81
If a difference exists between the manual velocity
measurements and the velocity sensor measurements, you can
compensate for this difference by adjusting cer ta in veloc ity
sensor parameters, particularly Maximum Velocity and
Sensitivity.
Note: If you change a device parameter, such as an
electronic offset, yo u must reactivate the monitor.
13. (optional) Click on the Read button again to take add itional
measurements, if necessary.
14. Click on the Close button once you are finished pe rforming
confirmations for the selected device to exit the Confirm
Device dialog.
15. Repeat steps 2 through 12 for each additional device that
includes a sensor(s) you want to confirm.
Note: If the location supports a second monitoring point,
remember to confirm the devices assigned to that
monitoring point, as necessary.
16. If a change has been made to any sensor parameter, reactivate
the monitor. See page 6-72 for more information on
reactivating a monitor. If y ou didn’t change any device
parameters, there is no need to reactivate the monitor.
17. Click on the green Hangup button in the Functions section to
disconnect from the monitor.
Qstart generates a log entry of the confirma tion activity, whic h
includes the field and monitor readings, the name of the crew,
and any associated comments, and saves it to the local
direc t ory or network. It also generates a log entry for each
user-initiated reading taken by the monitor that includes the
sensor fired, date and time at which the measurement was
taken, current device parameters corresponding to the sensor,
and reading and associated quality. These entries are
available for viewing through the log viewer in Qstart.