User Manual

Maintenance a n d Troubleshooting 10-5
LED STATUS window on monitor t op
Viewing Monitor Activity Codes
Monitor activities, such as reading sensors or transmitting/receiving
messages, display on the LED automatically in the form of
individual characters. Each character represents a specific activity.
Appendix C provides a list o f these characters and the activities to
which they correspond. The presence of a yellow light at the upper
left portion of the display indicates the monitor is awake or involved
in active communication.
Activating a nd Reading the Diagnostic Codes
The diagnostic information available through the LED c orre s ponds
to power and wireless communication, such as signal stre ngt h,
battery voltage, and I P address. These codes are particularly useful
during site investigation and system insta lla tion to ensure an
adequate and consistent signal strength, test communications, and
verify the monitor IP address.
Accessing and activating the diagnostic codes require you to prompt
the monitor with a sma ll magnet (ADS p/n 8000-0140). Activate
the diagnostic code sequence by holding the magnet against the red
dot (labeled WAKE) located above the LED window on the